NOTE:
You may encounter a new revision spring carrier. This
was an inline change made as a cost savings. Either version of
the spring carrier is acceptable to use.
Original Spring Carrier
8
Remove the spring adjuster (22) from the diaphragm clamp
(21) using a 6mm hex key. Using a LP air nozzle inserted into
the MP port, blast a small amount of air into the first stage to
remove the diaphragm (3). Keep your finger over the diaphragm
to prevent it from ejecting. Discard diaphragm.
CAUTION:
Never remove the diaphragm by prying or dig-
ging around the edges. This will cause irreversible dam-
age to the first stage body.
9
Remove the valve lifter (4) out of the first stage body (5).
Insert a 6mm hex key into the end of the turret retaining bolt
(15) and turn counter-clockwise to remove. Remove the spring
(12) and HP valve (11).
Revised Spring Carrier
10
Using the o-ring removal tool (PN 944022), remove the
o-ring (13) from the outside and o-ring (17) from the inside
of the turret retaining bolt (15). Discard both o-rings.
11
Lift out the o-ring (16) and blue thrust washer (14) from the
top of the turret (8). Remove o-ring (7) from the body (5).
Using a 5mm hex key, remove the remaining MP and HP blanking
plugs (9,19). Remove o-rings (10,20) from the blanking plugs.
Discard all o-rings.
Yoke Disassembly
1
Unscrew the yoke screw
(30) from the yoke clamp
(27). Remove the protective
cap (28) from the yoke screw
and pull the o-ring (29) off the
protective cap and discard.
2
Install first stage into bench vise and using a 3/4 inch closed
end wrench, remove the yoke clamp connector (32). Lift off the
yoke clamp (27) and distance piece (6).