Tsurumi Pump KTD Series Operation Manual

Submersible slurry pumps
Hide thumbs Also See for KTD Series:

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the KTD Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Tsurumi Pump KTD Series

  • Page 3 Be sure to thoroughly read and understand the SAFETY PRECAUTIONS given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section are intended to prevent danger or damage to you or to others.
  • Page 4 CAUTION Be sure to provide a ground wire Attach a hose securely to the hose coupling. Imperfect connection securely. Do not connect the ground wire to a gas pipe, water of hose could cause water leakage which may result in the pipe, lightening rod, or telephone ground wire.
  • Page 5 CAUTION doing so will damage the product, which may lead to electrical leakage or electrical shock. Deterioration of the insulation may lead to electrical leakage, electrical shock, or fire. Failure to observe this caution could cause it to malfunction or to operate abnormally, which may lead to electrical leakage or electrical shock.
  • Page 6 Hose Coupling Cabtyre Cable Handle Mechanical Seal Oil Lifter Oil Plug Lubricant Shaft Sleeve Impeller Pump Casing Suction Cover Agitator Connection Rod Agitator Strainer Stand...
  • Page 7 Submersible pump Rated voltage Built in motor protector Rated current Serial number Rated output power Model Insulation class Frequency Max. liquid temperature Max. total head Weight without cable Min. total head Speed of rotation Max. flow rate IP degree of protection Discharge bore Max.
  • Page 8 CAUTION Note: CAUTION Model Critical Pressure KTD22.0 , KTD33.0 0.5MPa (5kgf/cm ) — discharge pressure during use AC voltmeter AC ammeter Insulation resistance Wrenches for Wrenchs for connecting (tester) (clamp) tester fastening the power supply (megger tester) bolts and nuts (a screwdriver or a box wrench) Note: Note:...
  • Page 9 WARNING CAUTION Wire rope Note: CAUTION Note: Flow back Flow out Note: CAUTION...
  • Page 10 WARNING WARNING CAUTION CAUTION Cabtyre cable Connection Extension cable To prevent water from To avoid damaging the Never submerge the If the cabtyre cable must be ends of a cabtyre extended, use an extension entering inside the cable, arrange the cable cable, be sure to run so that the cable is not cable in water.
  • Page 11: Direct-On-Line Starting

    WARNING Direct-on-line starting Ground Green (Brown) (Green/Yellow) White Black (Blue or Grey) (Black) Green Ground Coil Black(Black) White(Blue or Grey) Circle thermal protector Red(Brown) CAUTION Note: Note:...
  • Page 12 WARNING CAUTION Note: WARNING Direct-on-line starting COUNTERMEASURE Ground (Example) Interchanging phases V and W COUNTERMEASURE COUNTERMEASURE CAUTION...
  • Page 13 CAUTION Note: WARNING CAUTION CAUTION Model C.W.L. KTD22.0 140mm C.W.L. KTD33.0 160mm...
  • Page 14 WARNING Note: Interval Inspection Item To be below the rated current Measure operating current EveryDay Measure power supply voltage Power supply voltage variation (within ±10% of the rated voltage) Measuring insulation resistance Insulation resistance reference value = 1M min. Note: The motor must be inspected if the insulation resistance is considerably lower than Monthly that obtained during the last inspection.
  • Page 15 Note: Oil filler inlet Packing Oil plug Wrench Model Oil Quantity KTD22.0 Note: KTD33.0 1,250 Part Replacement condition Mechanical seal When oil in oil compartment becomes milky. (non-additive) Lubricant : Turbine oil VG32 Every 4,000 hours of 12 months, whichever comes first. Packing and O-ring Each time pump is disassembled or inspected Oil seal...
  • Page 16 WARNING Note: CAUTION...
  • Page 17 Oil Seal Shaft Sleeve Impeller Adjusting Washer Impeller Plain Washer Agitator Connection Rod Packing Oil Plug Agitator Pump Casing Plain Washer Spring Washer Impeller Nut Packing Suction Cover Plain Washer Stud Bolt Strainer Stand Spring Washer Hex.Nut Note: Note:...
  • Page 18: Manufacturing Number

    WARNING No power is supplied Contact the electric power company or an Pump fails to start (i.e. power outage). electrical repair shop. Open circuit or poor connection Check if there is an open circuit in the cabtyre of the cabtyre cable. cable or wiring.

This manual is also suitable for:

Ktd22.0Ktd33.0