Connecting the Cables

Connect the cable to the indoor unit by con-
necting the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection. (Ensure that the color of the
wires of the outdoor unit and the terminal No.
are the same as those of the indoor unit.)
!
CAUTION
- The circuit diagram is a subject to
change without notice.
- The earth wire should be longer than the
common wires.
- When installing, refer to the circuit dia-
gram on the chassis cover.
- Connect the wires firmly so that they
may not be pulled out easily.
- Connect the wires according to color
codes, referring to the wiring diagram.
!
CAUTION
The power cord connected to the outdoor
unit should be complied with the following
specifications(UL recognized or CAS certi-
fied)
AWG_"A"
Capacity(Btu/h)
Power
9k/12k
"A"
14
The power connecting cable connected to the
indoor and outdoor unit should be complied
with the following specifications (UL recog-
nized or CAS certified).
AWG_"B"
Capacity(Btu/h)
Power
9k/12k
"B"
18
* Field wiring shall be done such that the cur-
rentcarrying conductors become taut before
the earthing conductor if the cord slips out of
the cord anchorage.
17