WATER DRAINAGE
This appliance is an advanced self-evaporating air conditioner, which reduces the need to empty the
water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the
condenser coils and any excess is evaporated. Please make sure that the rubber caps are firmly secured
on the water drainage points when the unit is running. In extreme humidity or while the unit is in reverse
heating mode, the internal water tank may fill quicker triggering the tank full alarm. When this occurs, the
display panel will show an Error Code: E4 – this indicates you will need to manually drain the water tank.
Manual Drainage:
•
When the internal water tank is full – Error code: E4 will be displayed on the control panel and
the unit will stop working
•
Turn off the unit and unplug from the mains socket
•
Place the water drainage hose into a suitable container
•
Remove the rubber cap from the drain point
•
Insert the drainage hose in to the hole
•
Water will drain into container
•
After the tank has been fully drained, remove the pipe and insert the rubber cap back into the
drain point
Continuous Drainage:
•
Turn off the unit and unplug from the mains socket
•
Place the water drainage hose into a suitable container or over a drain
•
Remove the rubber cap from the secondary drain point
•
Insert the drainage hose in to the hole
•
Once appliance is switched on, water will continuously drip from drainage hose
Note: Please be mindful that if you are using a container, you will need to manually
empty the container at regular intervals to ensure it doesn't overfill.
Note: Please do not use continuous drainage if you intend to use the self-
evaporating facility, for improved cooling effect.