Table 2-4 Sample Scenario One: Chain of Events
Event
1. At the start, input A and input B
are both present
2. Input A is lost
3. One second pass
4. Input A is present
5. Input B is lost
6. One second pass
The initial settings for sample scenario one are outlined in
Table 2-5 Sample Scenario Two: Parameter Settings
Parameter
DA Work Mode
AES Alarm Switch Level
AES Manual Switch
AES Alarm Switch Mode
AES Non-resetting Protection
AES A Loss of Audio: Priority
AES A Loss of Audio: Trigger
AES A Loss of Audio: Clear
AES B Loss of Audio: Priority
AES B Loss of Audio: Trigger
AES B Loss of Audio: Clear
Result
Output is A (A is the primary channel in 1x8 mode)
Output is A (alarm is not yet triggered; waiting for
one second trigger condition).
Output is B (alarm is triggered).
Output is B (Non-resetting mode)
Output is B (alarm is not yet triggered; waiting for
one second trigger condition).
Output is A (Non-resetting Protection is Switch to
A)
Table
Setting
1x8 Mode
6
Disable
Non-resetting
Stay with B
6
1.0 s
2.0 s
6
1.0 s
2.0 s
2-5.