8.5.1 AIR HANDLER ONLY (NON-HEAT KIT
MODELS)
The power supply connects to the stripped black and red wires
contained in the air handler electrical compartment. Attach the
supply wires to the air handler conductors as shown in the unit
wiring diagram using appropriately sized solderless connectors
or other NEC or CEC approved means. A ground lug is also
provided in the electrical compartment. The ground wire from
the power supply must be connected to this ground lug.
NOTE: AIR HANDLER WITH DISCONNECT SWITCH - Attach
the supply wires to the disconnect switch terminals as shown in
the unit wiring diagram using appropriately sized solderless
connectors or other NEC or CEC approved means. A ground
lug is also provided on the disconnect switch mount bracket
(Figure 18) in the electrical compartment. The ground wire from
the power supply must be connected to this ground lug.
8.5.2 AIR HANDLER / NON-CIRCUIT BREAKER
HEAT KITS
A terminal block is provided with the HKS kit to attach the power
supply and air handler connections. Follow the HKS
Installation Manual and wiring diagram for complete wiring details.
NOTE: AIR HANDLER WITH DISCONNECT SWITCH - Do not
use disconnect switch assembly inside the unit while
installing Heat kit. Refer Figure 18 to know how to remove
disconnect switch assembly from unit.
Figure 18
NOTE: TRANSFORMER SUB-ASSEMBLY –
Before installing the Heat Kit, uninstall the transformer sub-
assembly (Figure 19). Make sure to unplug 12 pin connector
before uninstalling the transformer sub-assembly. Follow the
Heat Kit Installation Manual to install the Heat Kit. Install
transformer sub-assembly back to the unit (Figure 19). Plug in
12-Pin connectors and secure screws while installing transformer
sub-assembly back to the unit after heater kit installation.
14
Figure 19
8.5.3 AIR HANDLER WITH CIRCUIT BREAKER
HEAT KIT
The circuit breakers have lugs for power supply connection. See
the HKS Installation Instructions for further details.
Use only specified wire and connects to terminals tightly. Be
careful that wires do not place external stress on terminals.
Keep wire in neat order; not to obstruct other equipment.
Make sure that the access panel closed tightly. Incomplete
connections could result in overheating, and in worse cases,
electric shock or fire.
Never connect power supply wiring to the terminal block for
remote controller wiring as this could damage the entire
system.
When doing the wiring, make sure the wiring is neat and
does not cause the access panel to stick up, and then close
the cover firmly. When attaching the electric component box
cover, make sure you do not pinch any wires.
PRECAUTIONS
Refer to the "REMOTE CONTROLLER INSTALLATION
MANUAL" on how to install and lay the wiring for the remote
controller.
See also the "Wiring Diagram Label" located inside the unit's
fan housing.
Connect the remote controller and transmission wiring their
respective terminal blocks.
English