Remote Fmb-X-2.5; Configuration Settings; Figure 3-5: Console Fmb-X-2.5 Plan View; Table 3-2: Sw1 Configuration Settings - Moog Focal 903 User Manual

High density (hd) fiber optic video/data multiplexer
Table of Contents

Advertisement

903-0628-00 Rev. 1
The FMB-X-2.5 also sounds a continuous audible alarm when an optical link fails in AUTO mode, even if the
other fiber has a valid link. This informs the operator of a fiber fault that otherwise might not be noticed, as the
switchover from one fiber to the other is often seamless. The alarm can be turned off by briefly forcing the
toggle switch to the active fiber in manual mode and then back to the automatic setting. The FMB-X-2.5 alarm
can also be disabled via software commands.
A plan view of the console FMB-X-2.5 is shown below. The 1310/1550 nm singlemode WDM coupler is not
visible and is mounted on the underside of the optical daughtercard below the dual LC bushings shown.
FIBER F1
ST BUSHING
FIBER F2
ST BUSHING

3.1.3 Configuration Settings

Switch configuration settings for the remote and console FMB-X-2.5 cards are given in the tables below. Note
that both DIP switches (SW1 and SW2) are typically configured at the factory and therefore the
settings should never be changed from their original positions.
High Density Backplanes
Standard Backplanes
Focal Technologies Corp.
OPTICAL
DAUGHTERCARD
SFP CAGE

Figure 3-5: Console FMB-X-2.5 Plan View

Table 3-2: SW1 Configuration Settings

Description
SW1:1

Remote FMB-X-2.5

Console FMB-X-2.5

Table 3-3: SW2 Configuration Settings

Description
Model 903-HD User's Guide – FMB-X-2.5
FIBER
SWITCH
SFP
TRANSCEIVER
SW1:2
SW1:3
ON
ON
ON
OFF
ON
ON
SW2:1
SW2:2
SW2:3
OFF
ON
OFF
OFF
RX 1310 nm
DIN 41612
96-PIN
BACKPLANE
CONNECTOR
TX 1550 nm
SW1:4
ON
ON
SW2:4
OFF
OFF
OFF
OFF