Download Print this page

Operation And Maintenance - Dimplex RFV-800 "D" Series Manual

Forced air heater

Advertisement

4. Insert approximately 15" (38cm) of supply wire into re-
cess box through knockout provided in upper left hand
corner (Figure 2b).
!
NOTE: Wire should be rated for a minimum of 75°C
(167°F)
5. Connect power supply to terminals provided marked L1
and L2. Ground wire should be secured to green ground
screw provided on side of heater assembly (Figure 1).
6. All units are factory prewired for operation with built-in
thermostat. If remote thermostat operation is required
follow appropriate wiring diagram located on inside of
recess box.
!
NOTE: For applications where the unit is to operate at
the lower wattage, see wiring diagram located on inside of
the recess box for appropriate jumper to remove.
7. Secure heater assembly to recess box using four (4) M4
screws previously removed.
Front Panel Installation
8. Remove trim frame from front panel assembly.
9. If tamper proof built-in or remote thermostat operation
is required, secure the louvered door to the front panel
using two (2) M3 screws (not included) through the holes
provided. The knob can then be removed and adjust-
ment of the thermostat can be made using a slotted
screwdriver through the front panel.
10. Check to see that the fan blade is free to turn and that
no residue remains in the unit. Front panel can then be
secured to assembly using four (4) M4.8 x 37 screws
provided.
11. Replace Front Panel (Grille), see Figure 3.
Figure 3
C
(A) Place frame over top of tabs.
(B) Push in at bottom until frame is flush with front panel.
(C) Insert two (2) screws to hold frame in place.
1367 Industrial Road
Cambridge ON Canada N3H 4W3
1-888-346-7539
www.dimplex.com
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2016 Dimplex North America Limited
A
C
B
Operation and
1. Set thermostat to desired temperature and both fan
and heat should come on. Note that when desired
temperature is reached the fan operation will continue for
a short period after the elements have de-energized in
order to remove residual heat from the unit.
2. The fan motor is permanently lubricated and sealed at
the factory and is maintenance free.
3. It is suggested that at the beginning of each season the
front panel is removed and the wire connection condition
is checked and the unit is cleaned of dust and dirt with a
vacuum cleaner.
!
NOTE: Always open the circuit breaker to disconnect
power to the unit prior to performing any maintenance or
service operation.
WARNING: Should the Over Temp light come on,
disconnect power to the heater or turn down the
thermostat fully counterclockwise and call a licensed
electrician. DO NOT USE HEATER UNTIL PROBLEM IS
DETERMINED AND FIXED.
Warranty
The Manufacturer warrants the heating elements and components of the
enclosed product against any defect in material or workmanship for a period
of one year from the date of purchase. In full satisfaction of any claims
under this Warranty the Manufacturer will repair or replace without charge, in
its factory or in the field as it alone may decide, any parts which in its opinion
are defective.
The Manufacturer shall not be responsible for any transportation or shipping
costs in relation to such repair or replacement except as specifically
assumed by it. Misuse of this product or repairs by persons other than the
Manufacturer's authorized personnel without the Manufacturer's written
approval, will void this Warranty.
This Warranty is in lieu of all other warranties or conditions whether express
or implied including but not limited to those of merchantability or fitness for
purpose and shall constitute the sole remedy of the Purchaser and the sole
liability of the Manufacturer in respect of the sale of the product, whether
in the nature of breach or breach of fundamental term, or of negligence or
otherwise.
The Manufacturer shall not be liable for any special, indirect or consequential
damages or for any damages resulting from removal or replacement of a
heater subject to warranty claim without the Manufacturer's authorization.
This Warranty is transferable by the original consumer purchaser of the
product. Any claims under this Warranty must be submitted in writing to
the Service Manager, Dimplex North America Ltd., 1367 Industrial Rd.,
Cambridge, Ontario N3H 4W3, Canada.
Maintenance

Advertisement

loading