Dimplex RFI Series Installation Instructions

Forced air heater rfi series;

Advertisement

Quick Links

Forced Air Heater
RFI Series

ImPORTAnT InSTRUCTIOnS

When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock
and injury to person, including the following:
1.
Read all instructions before using this heater.
2.
A heater has hot and arcing or sparking parts inside. Do
not use it in areas where gasoline, paint or flammable
liquids are used or stored.
3.
This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. If provided, use handles
when moving this heater. Keep combustible materials
such as: furniture, pillows, bedding, papers, clothes and
curtains away from heater.
4.
To prevent a possible fire, do not block air intakes or
exhaust in any manner. Do not use on soft surfaces like
a bed where openings may become blocked.
5.
Do not insert or allow foreign objects to enter any venti-
lation or exhaust opening as this may cause an electric
shock or fire, or damage the heater.

SAvE THESE InSTRUCTIOnS

Installation Instructions

WARnIng: Wiring procedures and connections should
be in accordance with the National Electric code (NEC &
CEC) and local codes.
!
nOTE: Each heater comes as two packages: the main
heater assembly and the associated grille kit.
CAUTIOn: Do not operate heater without the Grille
installed.
1.
Remove the main heater assembly from the carton. Re-
move the screws securing heater assembly and retaining
brackets to the recess box and separate. (Figure 1) .
!
nOTE: Mount the heater a minimum of 12" (30.5cm)
from the finished floor, and a minimum of 6" (15cm) from any
vertical surface if installed in the ceiling.
Recessed Installation
2.
The recess box provided with the heater is designed for
attachment between studs placed on 16" (40.6cm) cen-
tres. If different spacing exists, construct frame to suit
the box in order to avoid any vibration and noise caused
by loose mounting (Figure 2a).
3.
Note the orientation of box ("TOP" shown on recess
box) and secure to studs using four holes provided on
side flanges, ensuring these flanges are flush with fin-
ished surface of wall or ceiling (Figure 2b).
Surface Installation
2. Secure optional surface mount box (Part No. RFP8D)
by angling screws through holes provided in rear of
surface box into studs or finished surface.
3. Position recess box into surface box and secure with
four screws provided in parts bag of surface box.
Supply Wiring and Heater Installation
4.
Insert approximately 15" (38cm) of supply wire into
recess box through knockout provided in upper left hand
corner (Figure 2b). Wire should be rated for a minimum
of 75°C (167°F)
5.
Connect power supply to terminals provided marked L1
and L2. Ground wire should be secured to green ground
screw provided on side of heater assembly (Figure 1).
6.
All units are factory prewired for operation with built-in
thermostat. If remote thermostat operation is required
follow appropriate wiring diagram located on inside of
recess box.
!
nOTE: It is recommended that for ceiling mount applica-
tions a remote thermostat be used in order to provide supe-
rior temperature control.
!
nOTE: All wiring must comply with National Electrical
Code and local codes.
7.
Secure heater assembly into recess box using the four
M4 screws previously removed.
Front Panel Installation
8.
Remove trim frame and front panel (grille) from the
carton.
9.
If tamper proof built-in or remote thermostat operation
is required, secure the louvered door to the front panel
using 2 M3 screws (not included) through the holes pro-
vided. The knob can then be removed and adjustment
of the thermostat can be made using needle nose pliers
through the front panel.
10.
Install the front panel on the heater assembly. Check to
see that the fan blade is free to turn and that no residue
remains in the unit. Front panel can then be secured to
assembly using four M4.8 x 37 screws provided.
11.
Follow the steps as shown in Figure 3.
Figure 1
GROUND
SCREW
HEATER
ASSEMBLY
RECESS BOX
7211900100R00

Advertisement

loading

Summary of Contents for Dimplex RFI Series

  • Page 1: Important Instructions

    Forced Air Heater RFI Series Insert approximately 15” (38cm) of supply wire into ImPORTAnT InSTRUCTIOnS recess box through knockout provided in upper left hand corner (Figure 2b). Wire should be rated for a minimum When using electrical appliances, basic precautions should of 75°C (167°F)
  • Page 2 3. CONNECT LOAD SIDES OF REMOTE WALL THERMOSTAT TO MARR CONNECTORS "A" AND "B" AS SHOWN IN DIAGRAM. 4. CONNECT WIRE "A" TO INCOMING SUPPLY "L1". 5. CONNECT THE OTHER INCOMING POWER SUPPLY LINE TO THE OTHER LINE SIDE OF REMOTE WALL THERMOSTAT AS SHOWN. www.dimplex.com...
  • Page 3: Operation And Maintenance

    This Warranty is transferable by the original consumer purchaser of the product. Any claims under this Warranty must be submitted in writing to the Service Manager, Dimplex North America Ltd., 1367 Industrial Rd., Cambridge, Ontario N1R 7G8, Canada. Replacement Parts Fan Blade .

This manual is also suitable for:

Rfi815d31-kitRfi815d31w-kitRfi820d31-kitRfi820d31w-kitRfi820d41-kitRfi820d41w-kit ... Show all