Download Print this page
Dimplex RFV-800 "D" Series Manual
Dimplex RFV-800 "D" Series Manual

Dimplex RFV-800 "D" Series Manual

Forced air heater

Advertisement

Quick Links

Forced Air Heater
RFV-800 Series "D"

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock
and injury to person, including the following:
1. Read all instructions before using this heater.
2. A heater has hot and arcing or sparking parts inside. Do
not use it in areas where gasoline, paint or flammable
liquids are used or stored.
3. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. If provided, use handles
when moving this heater. Keep combustible materials
such as: furniture, pillows, bedding, papers, clothes and
curtains away from heater.
4. To prevent a possible fire, do not block air intakes or
exhaust in any manner. Do not use on soft surfaces like
a bed where openings may become blocked.
5. Do not insert or allow foreign objects to enter any venti-
lation or exhaust opening as this may cause an electric
shock or fire, or damage the heater.

SAVE THESE INSTRUCTIONS

Installation Instructions

WARNING: Wiring procedures and connections should
be in accordance with the National Electric code and local
codes.
1. Remove heater from carton. The front grille and trim can
be lifted off assembly, and placed in carton to prevent
damage. Remove screws securing heater assembly to
the recess box and separate (Figure 1).
!
NOTE: Mount the heater a minimum of 12 inches (30.5
cm) from the finished floor.
Recessed Installation
2. The recess box provided with the heater is designed for
Figure 1
GROUND
SCREW
FRONT PANEL
(GRILLE) & TRIM FRAME
HEATER
ASSEMBLY
RECESS BOX
attachment between studs placed on 16" (40.6cm) cen-
tres. If different spacing exists, construct frame to suit
the box in order to avoid any vibration and noise caused
by loose mounting (Figure 2a).
3. Note orientation of box ("TOP" shown on recess box)
and secure to studs using four holes provided on side
flanges, ensuring these flanges are flush with finished
surface of wall (Figure 2b).
Surface Installation
2.
Secure optional surface mount box (Part No. RFP8D) by
angling screws through holes provided in rear of surface
box into studs or finished surface.
3.
Position recess box into surface box and secure with
four screws provided in parts bag of surface box.
Supply Wiring and Heater Installation
!
NOTE: All wiring must comply with National Electrical
Code and local codes.
Figure 2
A
19 3/4"
[50cm]
min. 12"
[30.5cm]
B
SIDE FLANGES
15"
[38cm]
FINISHED WALL
SURFACE
FINISH FLOOR
14 1/4"
[36cm]
7/8"[22mm] DIA
KNOCKOUT
14 1/4"
[36cm]
19 3/4"
[50cm]
3 5/8"
[9cm]
min. 12"
[30.5cm]
7201010001R12

Advertisement

loading

Summary of Contents for Dimplex RFV-800 "D" Series

  • Page 1: Important Instructions

    Forced Air Heater RFV-800 Series “D” attachment between studs placed on 16” (40.6cm) cen- IMPORTANT INSTRUCTIONS tres. If different spacing exists, construct frame to suit the box in order to avoid any vibration and noise caused When using electrical appliances, basic precautions should by loose mounting (Figure 2a).
  • Page 2: Operation And Maintenance

    This Warranty is transferable by the original consumer purchaser of the product. Any claims under this Warranty must be submitted in writing to the Service Manager, Dimplex North America Ltd., 1367 Industrial Rd., Cambridge, Ontario N3H 4W3, Canada. (A) Place frame over top of tabs.