Stylus
2.5mm AF
Spring pressure within the probe causes the stylus
to sit in one unique position, and return to this position
following each stylus deflection.
Stylus pressure is set by Renishaw.
The user should only adjust spring pressure in special
circumstances e.g. excessive machine vibration or
insufficient pressure to support the stylus weight.
To adjust spring pressure, remove the probe head to
gain access to the spring pressure adjusting screw.
Slacken the locknut, and turn the adjusting screw
anticlockwise to reduce pressure (more sensitive)
or clockwise to increase pressure (less sensitive).
A stop prevents damage, which could be caused
by overtightening the adjusting screw.
Finally tighten the locknut to 1Nm (0.74lbf.ft) and
replace the probe head.

MAINTENANCE

STYLUS SPRING PRESSURE ADJUSTMENT

Gauging force
Align contact pins before
connecting probe head.
Locknut 7mm AF
Stop
Adjusting screw
2.0mm AF
when located in radio module
ENSURE THAT THE OMP IS KEPT
CLEAN. DO NOT ALLOW COOLANT
OR PARTICLES TO ENTER THE
PROBE.
STYLUS SPRING PRESSURE
ADJUSTMENT AND USE OF STYLI
OTHER THAN CALIBRATION
STYLUS TYPE, MAY CAUSE
REPEATABILITY TO DIFFER FROM
THE TEST CERTIFICATE RESULTS.
DO NOT rotate probe head
29