MP18 PROBE/ADAPTOR PLATE/SHANK ASSEMBLY
PROBE/SHANK MOUNTING
1.
Remove battery covers and battery
- see opposite.
2.
Tighten probe/adaptor plate screws A
to 5.1 Nm (3.76 lbf.ft) using special
4mm AF hexagon key (supplied in tool kit).
3.
Fully slacken four screws B.
4.
Grease two screws C, and fit into shank.
5.
Fit probe onto the shank, and visually
position the probe centrally relative to
the shank. Partially tighten screws C
to 2 - 3 Nm (1.47 - 2.2 lbf.ft).
6.
Mount the probe/shank assembly into
machine spindle.
STYLUS ON-CENTRE ADJUSTMENT
7.
Each of the four screws B will move the
probe relative to the shank, in the X or Y
direction as pressure is applied.
Tighten individually, backing off after
each movement.
8.
When the stylus tip run-out is less than
20µm, fully tighten screws C to 6 - 8 Nm
(4.4 - 5.9 lbf.ft).
9.
For final centering use screws B to move
the probe, progressively slackening on
one side and tightening the opposite screw,
as the final setting is approached, using
two hexagon keys.
Tip run out of 5µm (0.0002 in) should
be achievable.
10. It is important that all four screws B are
tight or tightened to 1,5 - 3,5 Nm
(1.1 - 2.6 lbf.ft) once the final setting
has been achieved.
11. When on-centre adjustment is completed,
replace battery and covers - see opposite.
Note :
1.
DURING ADJUSTMENT CARE SHOULD BE TAKEN NOT
TO ROTATE THE PROBE RELATIVE TO THE SHANK.
2.
IF A PROBE/SHANK UNIT IS ACCIDENTALLY DROPPED,
IT SHOULD BE CHECKED FOR ON-CENTRE POSITION.
3.
DO NOT HIT OR TAP THE PROBE TO ACHIEVE
ON-CENTRE ADJUSTMENT.
STYLUS ON-CENTRE ADJUSTMENT
Adaptor plate A-2107-0031
PROBE
B
C
SHANK
SHANK
2,5mm AF
B
PROBE
Special short arm
hexagon key 4mm AF
A
Adaptor plate
4mm AF
C