Philips Respironics EasyLife Instructions For Use Manual page 2

The easylife nasal mask
Table of Contents

Advertisement

Available languages

Available languages

and replace any components as necessary.
• If an additional exhalation device is added to the patient circuit, you may need to adjust the pressure
level to compensate for the additional leak of the exhalation device.
• Use of a nasal or full face mask may cause tooth, gum, or jaw soreness or aggravate an existing dental
condition. Consult your physician or dentist if symptoms occur.
Before Use Read and Understand the Instructions
• Hand wash the mask.
• Wash your face.
• Do not apply moisturizer/lotion to your
face or hands prior to handling/wearing
the mask.
Cleaning Instructions
Hand wash the mask before first use and
daily. The headgear should be hand washed
weekly, or as needed. The headgear does
not need to be removed for daily cleaning of
the mask.
1. Hand wash the mask and headgear
in warm water with a mild liquid dish
washing detergent.
Caution: Do not use bleach, alcohol,
cleaning solutions containing bleach or
alcohol, or cleaning solutions containing
conditioners or moisturizers.
Caution: Any deviation from these
instructions may impact the performance
of the product.
2. Rinse thoroughly with water and air dry
out of direct sunlight. Make sure the mask
is dry before use. Lay the headgear flat or
line dry. Do not place the headgear into
the dryer.
Warning: Inspect the mask for damage
or wear (cracking, crazing, tears, etc).
Discard and replace any components as necessary.
Institutional Disinfection
For multi-patient use in the hospital/institutional environment, use the Disinfection Guide
to reprocess the mask between patients. These instructions can be obtained by visiting us
online at www.philips.com/respironics or by contacting Philips Respironics Customer Service
at 1-800-345-6443 (USA or Canada) or at 1-724-387-4000.
Philips Respironics System One Resistance Control
Your mask when combined with a Philips Respironics System One device, provides optimal
resistance compensation. This mask value is X1 and should be set by your provider.
Notes:
• Compare the mask to the device. See your device manual if the values do not match.
• System One is not compatible with masks that use a separate exhalation device.
2
Figure 1
A = Forehead Pad Slot
B = Inner Sealing Cushion with Blue Flap
C = Forehead Pad
D = Attachment Tabs
E = Outer Support Cushion
F = Headgear Strap
G = Headgear Clip (Optional)
H = Exhalation Chip (Do not block or
remove)

Advertisement