Cooling Recommendations; Available Accessories - Aquacal Tropicool TC500 Operation Manual

Hide thumbs Also See for Tropicool TC500:
Table of Contents

Advertisement

3.3 Cooling Recommendations

The following recommendations will reduce the amount of time required to cool a pool or cold plunge
application. If unsure of equipment cooling capability, review equipment data plate. See "Identifying
Model Specifications" on page 17.
1. Confirm chiller mode has been set to cooling mode.
2. Set thermostat to desired water temperature.
3. Temporarily set the filter pump for continuous operation.
This will allow the Chiller the time required to cool the water at start-up.
l
After the water has reached the desired temperature, reset the filter pump to normal operating time-frames.
l

3.4 Available Accessories

Accessories may be purchased through an authorized dealer of AquaCal products.
For further assistance, please see "Contacting AquaCal AutoPilot, Inc." on page 1.
5 lb Bypass Valve Kit (# STK0135)
When high flow rates are outside recommended specifications, please use this kit or an alternative bypass valve
l
system.
This kit can be used to control excessive water flow through the chiller. It provides automatic flow adjustments
l
for most applications.
Condensation Drain Kit (# STK0202)
Used when condensation water flow must be directed to a specific location.
l
Automatic Sequencing Controller
An Automatic Sequencing Controller (ASC) provides easy control of all units from one lead unit and prevents the
l
simultaneous start-up of multiple chillers.
Site voltage drop is minimized and utilities are not subjected to large in-rush demands of electrical current.
l
Part number is based on number of chillers to be controlled. Call AquaCal
l
configuration. See "Contacting AquaCal AutoPilot, Inc." on page 1.
External Flow Relay (Grid Flow Switch ) Kit (0040S)
Used when the pool / spa elevation is higher than the chiller.
l
Also used for automatic pool / spa thermostat switching.
l
PLEASE NOTE -
The kit is not to be used on applications exceeding 50 PSI.
Plumbing Unions:
SIZE
PART NUMBER
2 INCH PLS2627
Remote Control Kit (STK0070)
A remote (wired) control kit allows for full control of the chiller from up to 100 feet from the equipment.
l
®
for assistance with correct
Page - 18