Before Installation; Description Of The Equipment; Main Components - Daikin FWD04ACTN6V3 Installation And Operation Manual

Ducted fan coil units
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
FWD
Read this manual attentively before starting up the unit. Do
not throw it away. Keep it in your files for future reference.
Improper installation or attachment of equipment or acces-
sories could result in electric chock, short-circuit, leaks, fire
or other damage to the equipment. Be sure only to use ac-
cessories made by Daikin which are specifically designed
for the use with the equipment and have them installed by a
professional.
If unsure of installation procedures or use, always contact
your Daikin dealer for advice and information.
B
efore installation
Installation and maintenance should be carried out by technical person-
nel qualified for this type of machine, in compliance with current safety
regulations.
When receiving the unit please check its state, verifying if any damage
occurred during transport.
Refer to the relevant technical sheets for installation and use of possible
accessories.
Identify model and version of the unit from the indications stated on the
carton package.
U
se and operating limits
Daikin shall not be held liable
- if the unit has been installed by non-qualified personnel,
- if the unit has been used improperly,
- if the unit has been used under conditions that are not permitted,
- if maintenance operations specified in this manual have not been
carried out,
- if non original spare parts have been used.
Keep the unit in its packaging until it is ready to be installed, to prevent
dust getting inside.
Air sucked by the unit must always be filtered. Always use the supplied
air filter.
If the unit is not used during winter, drain the water from the system to
prevent damage caused by the formation of ice. If antifreeze solutions
are used, check the freezing point.
Do not change the internal wiring or other parts of the unit.
Operating limits are shown here below; all other uses are considered
improper:
thermal carrier: water/glycol
water temperature: 5°C~95°C
maximum operating pressure: 10 bar
air temperature: –20°C~43°C
voltage tolerance: ±10%
ambient air humidity limit: RH < 85 % non-condensing
FWD
Ducted fan units
4PW17549-3
1
Ducted fan coil units
Selection of location:
Equipment designed for ambient air conditioning and intended for use in civil
comfort applications
do not install the unit in rooms where inflammable gases are pre-
sent
do not let water spray directly on the unit;
install the unit on ceilings or walls that bear its weight. Leave enou-
gh space all around for proper operation and maintenance of the
unit, taking into account all installed optional accessories.
never place the heating unit immediately under an electric plug-so-
cket.
d
escription of the eqUipment
The FWD range of air conditioning and hot-air heating units has been
implemented for conditioning rooms that require the installation of
ducted units.

Main components

Load bearing structure made of galvanized steel sheet of suitable
thickness, duly insulated with noise-proof/anti-condensing mate-
rial, self-extinguishing in class 1. Complete with inspection panels.
Fan unit with single or dual fan wheel, dual intake centrifugal type,
with statically and dynamically balanced impellers, coupled directly
to the 3-speed electric motor, equipped with permanently fit con-
denser and thermal safety device
Terminal strip.
Heat exchanger: high efficiency, made of copper tube and aluminium
fins secured to the tubes by mechanical expansion. They are fit
with brass manifolds and contain air valves. The heat exchanger,
normally supplied with left-hand attachments, may be turned 180°.
System for collecting and discharging condensate, setup either for cei-
ling or wall mounting. All FWD range models may be installed ei-
ther in a horizontal or in a vertical position.
Air intake module with air filter
Air intake module
Made of galvanised steel sheet. These modules permit to filter the
air sucked up by the unit and also to connect the unit to the intake
channelling.
Air filter
Made of acrylic material, self-extinguishing in class 1, with filtering
class EU 2.
The filter may be inserted or removed and is fixed by means of 2
knobs with M4 threaded stems.
The filtering material may be washed and regenerated to maintain
the rated filtering efficiency with limited charge leaks.
The accessory kit comprises
-
Load-bearing structure made of galvanised steel sheet
-
Removable cassette-type filter (to be pulled out like a drawer)
-
Self-tapping fixing screws
Example for installation
(See figure 1)
1
FWD unit
2
Intake module with air filter
Installation and
operation manual
Installation and operation manual