Installing A Management Module Blank; Installing I/O Modules - Extreme Networks BlackDiamond X8 Installation Manual

Hide thumbs Also See for BlackDiamond X8:
Table of Contents

Advertisement

9 Install module blanks in all remaining unoccupied slots.
Caution
All unoccupied management module slots in a BlackDiamond X8 series switch must have
module blanks correctly installed to ensure conformance to FCC requirements as well as to
maintain adequate airflow through the switch.

Installing a Management Module Blank

Install a blank management module in every unoccupied management slot.
Caution
If a management module is not installed in a slot, you must install a blank cover over the slot
to maintain proper EMI levels and ventilation, to ensure conformance to FCC requirements,
and to maintain adequate airflow through the switch.
1
Set the blank in place over the open slot.
2 Align and tighten the captive retaining screws.

Installing I/O Modules

Slots for I/O modules are numbered 1 through 8, starting at the top.
Caution
All unoccupied I/O module slots must be covered by I/O module blanks to ensure proper
system ventilation and EMI compliance. Individual I/O module blanks are purchased
separately from the chassis. See
blanks.
1
Attach the ESD-preventive wrist strap to your bare wrist.
2 If it is not already connected, connect the metal end to the receptacle between the management
module slots.
3 Holding the module by the metal rail and front panel only, remove the module from the antistatic
packaging.
Caution
To prevent ESD damage, never touch the components on the PCB or the pins on any of
the connectors.
BlackDiamond X8 Installation Manual
Installing BlackDiamond X8 Series Modules
Installing I/O Module Blanks
on page 24 to install I/O
22