7. Fit and secure pump cover
when required to complete set up
8. Optional external
pump over run switch
Use a retractive switch to briefly activate the pump.
This facility is for use when the wet area is being cleaned,
or for ritual cleansing. The pump will run for 15 seconds at
full speed to clear any water in the showering area.
The retractive switch shown is available from Screwfix.
(Retractive Switch 1 Gang 1 Way Part No. 6151J)
NOTE: This switch may only be fitted outside the wet area.

9. Transformer settings

The transformer is factory set for use in Bluetooth
technology mode with a 10 second overrun and 15mm Inlet
pipe diameter. Other settings are given below:
Flow Sensor Type:
1 Aux
2 Sika
3 Gems 1000ppl (pulses per litre)
4 Gems 2200ppl
5 Venturi
6 Mira Wired
7 Bluetooth
®
wireless
Off Delay
10s
30s
60s
Pipe Inlet
Diameter
1 / 15mm inlet pipe
(for electric showers only)
2 / 22mm inlet pipe
(for mixer showers)