Whale INSTANT MATCH SDP134T Installation Manuallines

Whale INSTANT MATCH SDP134T Installation Manuallines

With bluetooth wireless technology kit

Advertisement

Installation guidelines for Models
®
®
SDP134T Whale INSTANT MATCH
with Bluetooth
wireless technology Kit
For Installation Videos please refer to the Whale website:
www.whalepumps.com/psd
WITH
Technical Helpline: 0845 0694 253
This kit may be used with the following Mira Advance Shower:
Mira Advance Flex Extra 8.7kw 1.1785.005 (J09N)
www.youtube.com/WhaleHealthcare
300 000
Please leave this booklet with the end user
after installation and demonstration
WHALE KITS INSTALLED IN THE UK

Advertisement

Table of Contents
loading

Summary of Contents for Whale INSTANT MATCH SDP134T

  • Page 1 ® ® SDP134T Whale INSTANT MATCH with Bluetooth wireless technology Kit For Installation Videos please refer to the Whale website: www.whalepumps.com/psd WITH Technical Helpline: 0845 0694 253 This kit may be used with the following Mira Advance Shower: Mira Advance Flex Extra 8.7kw 1.1785.005 (J09N) www.youtube.com/WhaleHealthcare...
  • Page 2: User Warnings

    6. How do I register my warranty? Please complete and return the warranty registration form supplied with your pump, www.whalepumps.com/psd or complete the online form at: 0845 0694 253 info@whalepumps.com www.whalepumps.com/psd Whale, 2 Enterprise Road, Bangor, Co. Down, @Whalecare BT19 7TA, N.Ireland...
  • Page 3: Principles Of Operation

    Principles of Operation ® ® This kit has been designed for the pumping of shower waste water. The Whale Instant Match with Bluetooth wireless technology control unit uses the flow signal from the shower to measure the flow rate of water into the shower. The control unit uses the signals sent from the flow sensor to adjust the pump speed to match the flow of water from the shower.
  • Page 4: Table Of Contents

    lumbing of the Waste Pipe Index User warnings End user help Principles of operation Plumbing specification Plumbing gulley Plumbing of waste pipe Installation Transformer settings ® Bluetooth wireless technology setup ® Bluetooth wireless technology unpairing Hardwired setup Purge cycle Swapping pump & transformer on backplate Safety warning Installation testing and repair EU declaration of conformity...
  • Page 5: Plumbing Specification

    FALL WHERE THE PIPE LENGTH IS GREATER THAN 1M. WARNING IF LESS THAN 1M USE 22MM PIPE ® • The Whale pump is IP45 compliant. Locate pump in accordance with BS7671: 2008 Part 7 (17th Edition). The pump may be installed in bathroom zones 1, 2 or 3.
  • Page 6: Plumbing Gulley

    Fig 1.2 • Rotate the pump head if necessary. Loosen clamping ring screw, rotate and retighten as shown. See Fig 1.2 • Before commissioning the shower and running water through the system, ensure that the shower area and gulley are completely free of building debris, especially tile grout, screed material and latex.
  • Page 7: Plumbing Of Waste Pipe

    32mm (1 ") McAlpine examples and the McAlpine catalogue for other variants. Use with a Macerator Pump ® • Discharge from the Whale pump must go into the top of the macerator box. Do not use the bottom entries. 32mm ") 1 /4 See Fig 1.6...
  • Page 8: Installation

    umbing of the Waste Pipe Installation 1. Plumbing drainage pipe • Run 15mm pipe from gulley to pump inlet (max 3m). • Use slow radius bends where possible. Full size elbows are acceptable, not stem or Male/Female elbows. Where possible avoid attaching elbows directly to the pump. 2.
  • Page 9 3. Mounting your pump to the wall • Mark the hole centres through unit backplate. • Drill holes in wall and fit wall plugs (if necessary). Use 6mm masonry bit. • Secure the backplate to the wall using supplied screws. •...
  • Page 10 (see page 11). • Refit the hatch and tighten the screws to make the transformer water resistant. ® ® The Whale Instant Match with Bluetooth wireless technology transformer includes Activelink diagnostics to aid installation: On the transformer are two indicator LEDs •...
  • Page 11: Transformer Settings

    7. Fit and secure pump cover when required to complete set up 8. Optional external pump over run switch Use a retractive switch to briefly activate the pump. This facility is for use when the wet area is being cleaned, or for ritual cleansing.
  • Page 12: Bluetooth ® Wireless Technology Setup

    ® • The Bluetooth function of the Whale Instant Match transformer will only work with the Mira Advanced Flex ® Extra (J09N) shower. Previous Whale Instant Match Wireless transformers cannot be connected wirelessly ® ® to the Bluetooth wireless technology enabled Mira Advance shower ®...
  • Page 13 2. Transformer set up • Switch the mains electric supply to the transformer ON. The light on the transformer will now flash red to indicate ® that a Bluetooth wireless technology connection has not yet been established. • Press and hold the blue test button on the transformer until the the light flashes red and green to indicate that the transformer is now in pairing mode.
  • Page 14 • The status light on the shower will then flash white to indicate that the transformer has successfully been paired to the shower. • The Whale transformer will flash green only to indicate that it is paired to the Mira shower 7.
  • Page 15: Bluetooth ® Wireless Technology Unpairing

    PCB board may require the Bluetooth wireless technology connection ® between the shower and Whale Instant Match transformer to be terminated and paired again once the work has been completed. To unpair the transformer from the shower, please follow these steps.
  • Page 16: Hardwired Setup

    2. Shower Settings • Please ensure that the “Pump LK1” switch inside the Mira Advance (J09N) has been set to the “OFF” position as per the diagram shown. NOTE: Switch settings for other Whale transformers can be found on page 17.
  • Page 17 LK1 - ON Hardwired 755.299 LK1 - OFF Hardwired 755.349 LK1 - OFF Hardwired Older models of Whale transformer can be connected to the 755.399 LK1 - OFF Hardwired ® Mira Advance Flex Extra (J09N) shower. This table shows the 755.449...
  • Page 18: Purge Cycle

    • External components for service are jumper settings only. • Where there is damage to the transformer or cabling, contact your Whale distributor for a replacement. • Do not connect mains power to the pump as this will cause permanent damage and will result in an electrical hazard.
  • Page 19: Installation Testing And Repair

    CHECK TRICUSPID VALVE - Remove the tricuspid valve Installation Testing & Repair holder screwed onto the pump discharge. Remove the rubber valve and assess its condition. If it is worn or stiff then change The pump system is designed not to require maintenance. If and re-test.
  • Page 20: Eu Declaration Of Conformity

    Richard Bovill IEC 60335-1:2010+AMD1:2013 edition 5.1 Engineering Director EN 60335 2 41:2003 + A1:2004 + A2:2010 EN 60335 1:2012 Whale 2 Enterprise Road, Bangor, EMC:    Co. Down, BT19 7TA, UK BS EN 55014-1:2006 + A2:2011 Technical Helpline: 0845 0694 253 BS EN 55014-2:2015 whalepumps.com...
  • Page 21: Specification

    Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Maximum Head & Lift: 1.5m Whale. Whale’s policy is one of continuous improvement and we reserve the Transformer right to change specifications without prior notice. Illustrations are for guid- ance purposes only.
  • Page 22: List Of Parts Included In The Kit

    umbing of the Waste Pipe List of Parts included in the kit Item Part No. Shower Drain Pump SDS021T Transformer Instant Match Bluetooth SDS236T Pump Cover base 755.610 Wet Floor Gulley (vinyl floors) 755.274 Tray Gulley (50mm) 755.108 Tricuspid valve 755.57 Rubber Waste adapter 2 parts 22mm –...
  • Page 23 Pump base standoff’s Where pipe runs make installation of the pump base difficult we recommend the use of a Space - Plug (Available from SCREWFIX Version 30-50mm shown below)
  • Page 24: Fault Diagnosis

    ® Whale INSTANT MATCH Kit Fault Diagnosis What is the fault? Pump will not start Pump will not stop The transformer allows the pump to Ensure power is connected and switched on. over-run for up to 60 seconds. If the pump continues to run after Press the TEST button on top of the transformer.
  • Page 25 Pump does not pump properly Ensure gulley is not blocked and that fittings are pushed home and airtight. Re-test and if pump does not pump properly, remove inlet coupling and press the test button on the transformer, or run the shower into the sink to run the pump.
  • Page 26: Product Dimensions

    Plumbing Specification WASTE PIPE FORMED BEND Maximum pipe length is 3m from gulley to pump. Pipe from gulley to pump must be in 15mm. MIN 1:40 FALL (Do not use 22mm pipework for 1M (MAX) electric showers. This will increase gulley noise.) WARNING 15MM DIA PIPE USE ONLY 22MM...
  • Page 27 Pump - SDS021T 310mm 255mm 127mm TRICUSPID VALVE Contact the Technical Helpline If you need further assistance: 0845 0694 253...
  • Page 28 0845 0694 253 info@whalepumps.com www.whalepumps.com/psd Whale, 2 Enterprise Road, Bangor, Co. Down, @Whalecare BT19 7TA, N.Ireland ref 181.604_v2_0118...

Table of Contents