Friedrich MD24Y3J Svc Manual page 81

Single zone air conditioner
Hide thumbs Also See for MD24Y3J:
Table of Contents

Advertisement

Display
Title
code
Heatsink High error
62
n Error Diagnosis and Countermeasure Flow Chart
Is installation
condition normal ?
Yes
Is assemble condition
of INV PCB heatsink normal ?
Yes
Is PCB temperature
sensing part normal ?
Yes
Recheck installation condition
and connection of Heat sink
Check Point
1. Check resistance between No.19 pin and NO.20 pin of PCB PFC module
2. Resistance value should be in 7kΩ ±10%.(at 25°C).
Only for training and service purposes
Cause of error
Inverter PCB heatsink
temperature is over 85°C
1. Check fan locking
2. Check covering of heat exchanger
3. Check distance between ODU and obstacles
No
4. Check pipe distortion and abnormality
5. Check service valve is opened
→ Eliminate causes for abnormal condition
Check assemble condition between INV PCB heatsink and
No
PFC & IPM module → Reassemble if abnormality found
Check resistance between NO.19 pin and NO.20 pin
No
of PFC module
→ Replace PCB if abnormality found
- 81 -
Check point & Normal condition
1. ODU fan locking
2. Heatsink assembly of INV PCB assemble condi-
tion abnormal
3. Defect of temperature sensing circuit part defect
of INV PCB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md36y3jMc24y3jMc36y3jMr24uy3jMr36uy3j

Table of Contents