Error Indicator (Outdoor) - Friedrich MD24Y3J Svc Manual

Single zone air conditioner
Hide thumbs Also See for MD24Y3J:
Table of Contents

Advertisement

1.2 Error Indicator (Outdoor)

2 Times
2 Times
LED01G
(RED)
1 Sec.
1 Sec.
1 Time
LED02G
(GREEN)
2 Sec.
MR24UY3J
Error Code
21
DC Peak(IPM Fault)
22
Max. CT(CT2)
23
DC Link Low Volt.
24
Pressure switch/Heater Sink.
26
DC Comp Position Error
27
PFC Fault Error
29
Comp Over Current
32
D-Pipe High(Inv.)
40
CT Sensor(Open/Short)
41
Inv. D-Pipe Th Error(Open/Short)
43
High Pressure Sensor(Open/Short)
44
Outdoor air Th Error(Open/Short)
45
Cond. Middle Pipe Th Error(Open/Short)
46
Suction Pipe Th Error(Open/Short)
48
Cond. Out-Pipe Th Error(Open/Short)
51
Capacity over
Communication Error(Indoor ÷ Outdoor)
53
60
EEPROM Error(Outdoor)
61
Cond. Middle Pipe High
62
Heatsink Error(High)
65
Heatsink Th Error(Open/Short)
67
BLDC motor fan lock(Outdoor)
If abnormal voltage is supplied, the protection circuits will turn off the product in order to prevent the component
damage. The product will automatically restart after 3 minutes.
Only for training and service purposes
2 Times
Outdoor Error
Ex) Error 21 (DC Peack)
1 Sec.
1 Time
1 Time
2 Sec.
MR36UY3J
Description
LED 1
(Red)
2times ◑
2times ◑
2times ◑
2times ◑
2times ◑
2times ◑
2times ◑
3times ◑
4times ◑
4times ◑
4times ◑
4times ◑
4times ◑
4times ◑
4times ◑
5times ◑
5times ◑
6times ◑
6times ◑
6times ◑
6times ◑
6times ◑
- 39 -
LED 2
Indoor
(Green)
status
1time ◑
OFF
2times ◑
OFF
3times ◑
OFF
4times ◑
OFF
6times ◑
OFF
7times ◑
OFF
9times ◑
OFF
2times ◑
OFF
0
OFF
1time ◑
OFF
3times ◑
OFF
4times ◑
OFF
5times ◑
OFF
6times ◑
OFF
8time ◑
OFF
1times ◑
OFF
3times ◑
OFF
0
OFF
1times ◑
OFF
2times ◑
OFF
5times ◑
OFF
7times ◑
OFF