When performing duct connections to the furnace supply
duct, use metal ducts appropriately sized to support the
additional airflow produced by the unit.
Stale air from building ductwork:
Cut an opening into the furnace return duct at least 10 feet (3.1 m) (A + B) away
from the furnace.
Connect this opening to the stale air from building port of the HRV/ERV (as
illustrated).
Fresh air to building ductwork:
Cut an opening into the furnace supply duct at least 18 inches (0.5 m) away from
the furnace.
Connect this opening to the fresh air to building port of the HRV/ERV (use metal
ducts, see illustration at right).
Make sure that the HRV/ERV duct forms an elbow inside the furnace ductwork.
NOTE : For this type of installation, it is recommended, however, not essential, that the
furnace blower be synchronized with the unit.
5.4.5 S
I
IMPLIFIED
NSTALLATION
Fresh air to building ductwork:
Cut an opening into the furnace return duct at least 10 feet (3 m) away from the
furnace.
Connect this opening to the fresh air to building port of the HRV/ERV (use metal
ducts, see illustration at right).
Stale air from building ductwork:
Cut an opening into the furnace return at least 3 feet (1 m) ahead of the fresh air
to building ductwork connection to the furnace return.
Connect this opening to the stale air from building port of the HRV/ERV.
Make sure that both connections to the furnace return duct are at least 3 feet (1 m)
apart.
For this type of installation, the furnace must always be
synchronized with the unit. See section 8.
5.5 I
E
NSTALLING THE
XTERIOR
Refer to illustration at right to connect the insulated duct to the hoods. An "Anti-Gust
Intake Hood" should be installed in regions where a lot of snow is expected to fall.
Make sure that both hoods are at least 18 inches above the
ground and that the intake hood is at least 6 feet (1.8  m)
away from any of the following:
Exhaust hood
Dryer exhaust, high efficiency furnace vent, central
vacuum vent
Gas meter exhaust, gas barbecue-grill
Any exhaust from a combustion source
Garbage bin and any other source of contamination
- R
/S
ETURN
UPPLY
CAUTION
- R
/R
ETURN
ETURN
CAUTION
H
OODS
WARNING
VH0140
VH0141
E
XHAUST
H
OOD
18"
(457
MM
(1.8
C
AULKING
VD0028
9
18" (0.5
MINIMUM
A
A + B =
10' (3.1
A
A
T LEAST
3' (1
)
M
A + B =
6" ø
(152
)
MM
I
NTAKE
H
OOD
)
18"
6'
(457
)
MM
)
M
O
PTIONAL
T
APE AND DUCT TIE
DUCT LOCATION
)
M
B
AT LEAST
)
M
B
AT LEAST
10' (3.1
)
M
6'
(1.8
)
M
18"
(457
)
MM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents