Single Line Descriptions - Emerson SM-I/O 24V Protected User Manual

Table of Contents

Advertisement

5.2

Single line descriptions

Parameter
x.01
Solutions Module ID
x.02
Solutions Module Main Software Version
x.03
T5 digital I/O 3 state
x.04
T6 digital I/O 4 state**
x.05
T7 digital input 5 state
x.06
T8 digital input 6 state
x.07
T9 digital input 7 state
x.08
Relay 1 state
x.09
T3 digital I/O 1 state
x.10
T4 digital I/O 2 state
x.11
T3 digital I/O 1 invert
x.12
T4 digital I/O 2 invert
x.13
T5 digital I/O 3 invert
x.14
T6 digital I/O 4 invert**
x.15
T7 digital input 5 invert
x.16
T8 digital input 6 invert
x.17
T9 digital input 7 invert
x.18
Relay 1 invert
x.19
Not used
x.20
Digital I/O read word
x.21
T3 digital I/O 1 source/destination
x.22
T4 digital I/O 2 source/destination
x.23
T5 digital I/O 3 source/destination
x.24
T6 digital I/O 4 source/destination***
x.25
T7 digital input 5 destination
x.26
T8 digital input 6 destination
x.27
T9 digital input 7 destination
x.28
Relay 1 source
x.29* T6 digital I/O 4 output select
x.30
Not used
x.31
T3 digital I/O 1 output select
x.32
T4 digital I/O 2 output select
x.33
T5 digital I/O 3 output select
x.34
Not used
x.35
Not used
x.36
Not used
x.37
Not used
x.38
Not used
x.39
Analogue output mode
x.40
Relay 2 state
x.41
Not used
x.42
Relay 2 invert
x.43
Relay 2 source
x.44
Not used
x.45* Analogue output 2 scaling
x.46
Not used
x.47* Analogue output 2 source
x.48
Analogue output 1 source
x.49
Analogue output 1 scaling
x.50
Solutions Module error status
x.51
Solutions Module software sub-version
*
Parameter not available with Commander SK
**
Digital input only with Commander SK
***
Destination only with Commander SK
18
Range( )
0 to 599
0.00 to 99.99
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 255
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0-20, 20-0, 4-20, 20-4
OFF (0) or On (1)
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
0.000 to 4.000
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0.000 to 4.000
0 to 255
0 to 99
www.controltechniques.com
Default( )
205
RO Uni
RO Uni
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
RO Uni
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni
On (1)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
OFF (0)
RW
Bit
0-20
RW Uni
RO
Bit
OFF (0)
RW
Bit
Pr 0.00
RW Uni
1.000
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
1.000
RW Uni
RO Uni
RO Uni
SM-I/O 24V Protected User Guide
Issue Number: 2
Type
PT US
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
US
US
US
US
US
US
US
US
NC PT
US
US
US
US
US
US
US
US
US
US
US
US
US
NC PT
US
US
US
US
US
US
NC PT
NC PT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents