Note
You can download these documents from

I/O Connector

Caution
This NI product must be operated with shielded cables and accessories to ensure
compliance with the Electromagnetic Compatibility (EMC) requirements defined in the
Specifications
they are installed in a shielded enclosure with properly designed and shielded input/output
ports and connected to the NI product using a shielded cable. If unshielded cables or
accessories are not properly installed and shielded, the EMC specifications for the product
are no longer guaranteed.
Caution
Do not make connections to the digital I/O that exceed the maximum I/O
specifications. Doing so may permanently damage the NI 6509 device and the computer.
Refer to the
maximum I/O specifications.
© National Instruments Corporation
The following documents contain information that you may find helpful as
you use this user guide:
DAQ Getting Started guides—These guides describe how to install the
NI-DAQmx driver software, the DAQ device, and how to confirm that
the device is operating properly.
NI-DAQmx Help—This help file contains information about using
NI-DAQmx to program NI devices. NI-DAQmx is the software you
use to communicate with and control National Instruments DAQ
devices.
Measurement & Automation Explorer Help for NI-DAQmx—This
help file contains information about configuring and testing DAQ
devices using MAX for NI-DAQmx, and information about special
considerations for operating systems.
DAQ Assistant Help—This help file contains information about
creating and configuring channels, tasks, and scales using the
DAQ Assistant.
section of this document. Do not use unshielded cables or accessories unless
The 100-pin high-density SCSI connector on the NI 6509 provides access
to 96 digital inputs and outputs. Use this connector to connect to external
devices, such as solid-state relays (SSRs) and LEDs. For easy connection
to the digital I/O connector, use the SH100-100-F shielded digital I/O cable
with the SCB-100 connector block, or use the R1005050 ribbon cable with
the CB-50 or CB-50LP connector block.
Signal Descriptions
and
ni.com/manuals
Specifications
sections for information about the
9
.
NI 6509 User Guide and Specifications