TABLE OF CONTENTS Table of contents Specifications 3-11 FOR THE INSTALLER Introduction Storage bin Standard legs Important operating requirements Select location Storage bin Ice machine Air Baffle Stacking instructions FOR THE PLUMBER Conform to all applicable codesWater inlet Drains For the electrician Electrical connections Final check list START-UP...
SPECIFICATIONS MODULAR CUBER NW 308/508 Ice Making Capacity ...
Page 5
NOTE.To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on page 34&35 of this manual. ...
Page 7
SPECIFICATIONS MODULAR CUBER NW 458 Ice Making Capacity NOTE.To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on page 34&35 of this manual. ...
Page 9
SPECIFICATIONS MODULAR CUBER NW608 Ice Making Capacity NOTE.To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on page 34&35 of this manual. ...
Page 11
SPECIFICATIONS MODULAR CUBER NW1008 Ice Making Capacity NOTE.To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on page 34&35 of this manual. ...
15 cm. minimum left, right, and rear for air-cooled models. STORAGE BIN The Scotsman bins for these units are the NB 393, NB530 and NB948. INSTALLATION NOTE: Allow 15 minimum Other bins may be available with bin tops to space at sides and back for ventilation and vary the storage capacity.
Page 15 ICE MACHINE AIR BAFFLE The use of a mechanical lift is recommended Install on the back side of the machine the air for lifting the uncrated icemaker onto the bin. baffle as per instruction provided with it. Remove front, top and sides panels. Place the unit directly onto the bin, align it with the back of the bin.
FOR THE PLUMBER build-up on parts in the water system. Heavily chlorinated water can be controlled using charcoal or carbon filters. CONFORM TO ALL APPLICABLE CODES WATER INLET DRAINS AIR-COOLED MODELS: The recommended AIR-COOLED MODELS: There is one 20 mm. water supply is cold water connected to the - diameter sump drain fitting at the back of the 3/4'’...
NOTE: All SCOTSMAN Cubers require a neutral wire and a solid earth ground wire to prevent possible severe Electrical Shock Injury to individuals or extensive damage to equipments.
Water Level Sensor. START-UP START-UP CYCLE 1.Open the water tap/valve and switch ON the power on the electrical supply line. 2.The models NW308-508-458- 608-808 enter in the Start Up cycle with Board energized, andNW1008 enter in 90 minutes delay time controlled by PC Board, The LED of ICE MAKING blinking slow.
9. First freezing time will range between 15 This screw position determines the distance and 20 minutes. Longer time for temperature between the sensor reeds and the egg-crate evaporator thus keeping the ice cube at a above 25℃ and shorter time required when proper thickness.
Page 19 OPERATION FREEZE CYCLE REFRIGERATION SYSTEM SCHEMATIC REFRIGERATION DURING FREEZE: evaporator section of the refrigeration system. This ice machine employs either air or water This is determined by the temperature of the as a condensing media, the refrigeration TXV sensing bulb, located on the suction line system for either one is a follows: manifold, at the outlet of the evaporator.
FREEZE CYCLE WATER SYSTEM A combination of a solenoid water inlet valve the evaporator surface by gravity. As it flows with a water level sensor is used to control the across the refrigerated evaporator, some of level of the water into the reservoir or sump. the water will be chilled enough to change A pump, running continuously, after the first form, turn to ice, and stay frozen onto the...
HARVEST CYCLE REFRIGERATION SYSTEM SCHEMATIC REFRIGERATION SYSTEM DURING All water remained in the reservoir at the end HARVEST of freezing cycle is pumped-out, to the waste, through the water purge valve and drain line, The refrigeration system performs the harvest eliminating possible build-up...
CONTROL SEQUENCE BIN FULL LED. The machine will restart when the ice deflector At the start of the freezing cycle, the contacts will be back in its normal vertical position of the magnetic switch mechanically operated provided that 3' are elapsed from unit stop. If bythe actuator plate of the deflector cover are not the machine will delay its restart till 3' are closed, thereby - via PC board - closing the...
Page 24
The fifth red LED is on steady: Both the fourth red LED and Too High discharge pressure, second green LED are blinking higher than 33 bar (460 PSI) fast: For the first 2 times, machine will 5 times too long Freeze Cycle automatic reset when pressure time drop down.
PC BOARD SET UP Fill water in first 4’ in freezing cycle The PC Board can be set up for: Fill water in first 10’in freezing cycle MANUAL RESET MODE To Restart the machine it is necessary to #6 Water purge control Push the MODE Button #6-OFF/#7-OFF Water pump work 30”...
COMPONENT DESCRIPTION Front Console Panel BUTTONA Reset/Washing LEDNo.1 Alarm high pressure LEDNo.2 Alarm LEDNo.3 Bin full. LEDNo.4 Operation LEDNo.5 Electrical power supply NW SERIES Power in (liver line) Compressor contactor Water inlet valve & Water pump & Water purge valve & Harvest valve & Fan motor Ice thickness sensor Fuse ...
Page 28
components output, and two buttons for The condenser temperature sensor probe MODE and clean, and one DIP Switch for PC (located in contact with the condenser tube board setup. coil) detects condenser temperature variations and signals them by supplying 3. Compressor Contactor current, at low voltage, to the P.C.
Page 29
sump to the tee. From there water is channeled through the vertical PVC tube to the water distributors, above the evaporator 15. Water level sensor plate, and from the holes in the distributor tube The Water Level Sensor, located on the upper water flows to the cells on one side of the right side of the water sump, works in evaporator plate.
Page 30
NW 308/508- WIRING DIAGRAM 220 V. 50 /60 Hz. 1 ph. br = brown r = red b = blue o = orange gy = yellow / green p = purple w = white g =green bk= black y =yellow I -PC BOARD A- TERMINAL BLOCK J- MAX PRESSURE SWITCH...
Page 31
Page 28 NW 458/608- WIRING DIAGRAM 220 V. 50 /60 Hz. 1 ph. n = black m = brown r = red bc = blue a = orange gv = yellow / green v = purple b = white B - Compressor contactor N - Water purge valve C - Compressor...
Page 32
Page 28 NW 1008 - WIRING DIAGRAM 220 V. 50 /60 Hz. 1 ph. r = red m = brown a = orange bc = blue v = purple gv = yellow / green g = green b = white y = yellow n = black A - Input terminal board...
Page 33
Page 28 NW 1008 - WIRING DIAGRAM 380 V. 50 Hz. 3 ph. r = red m = brown a = orange bc = blue v = purple gv = yellow / green g = green b = white n = black A - Input terminal board J -High pressure controller...
Page 34
Page 30 SERVICE DIAGNOSIS Reference to other portions of this manual, including wiring diagrams, installation, and The table below is intended as a quick operation recommended better reference to aid the Service Agent in determine the cause of a problem. determining the cause of a particular type of malfunction, as well as the recommended repair.
Page 35
MAINTENANCE & CLEANING & SANITATION INSTRUCTIONS A SCOTSMAN Ice System represents a 5. Check and tighten all bolts and screws. sizable investment of time and money in any company’s business. In order to receive the 6. Check for water leaks and make corrections.
Page 36
250 cc - NW1008 350 cc of Scotsman Ice Machine Cleaner directly into 9. Pour hot water into the storage bin melt the the reservoir while the water inlet valve will be cubes, and to also clean the bin drain.
Page 37
Scotsman Ice Systems (Shanghai) Co., Ltd. Fax:0086-21-61313330 Address: Hotline:0086-4006300076 Room 2505, Building 2, No 20 Xuhong Middle Rd, Shanghai, China. 200235 E-Mail: sales@scotsman-china.com Phone:0086-21-61313200 Website:www.scotsman-china.com ...
Need help?
Do you have a question about the NW308 and is the answer not in the manual?
Questions and answers