Scotsman NW308 Service Manual page 24

Electronic modular cubers
Hide thumbs Also See for NW308:
Table of Contents

Advertisement

The fifth red LED is on steady:
Too High discharge pressure,
higher than 33 bar (460 PSI)
For the first 2 times, machine will
automatic reset when pressure
drop down. and the machine will
stop when high temperature occurs
the third time, ice machine will
stop,
Reset mode:
And press MODE button can go to
start up cycle.
Both the third yellow LED and forth
red LED are blinking fast:
Ice thickness sensor fault
When machine start, if PC board
detect
machine will stop.
Reset mode:
And press MODE button can go to
start up cycle.
 
the
ice
thickness
ON,
23
Both the fourth red LED and
second green LED are blinking
fast:
5 times too long Freeze Cycle
time
Reset mode:
And press MODE button can go to
start up cycle.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nw508Nw458Nw1008Nw608

Table of Contents