Samsung MWR-WE11N Installation Manual page 20

Wired remote controller, air conditioner
Hide thumbs Also See for MWR-WE11N:
Table of Contents

Advertisement

Wired Remote Controller Installation/Service Mode
AA
Main
Sub
menu
menu
1
2
3
4
5
Indoor unit option checking (1)
3
6
Indoor unit option checking (2)
1
2
4
option setting 2)*
3
4
7
1
5
2
temperature of the indoor unit
Fresh Duct discharge
3
temperature checking
1
ERV Plus temperature
2
6
3
Heating EEV control for ERV Plus
4
5
checking
1
(F3F4 line Indoor unit master)
2
7
Mode master indoor unit
3
(F1F2 line Indoor unit master) 3)*
4
20
Function
Indoor unit room temperature
Indoor unit EEV step
Use of central control
Use of drain pump
Use of electric heater
Use of hot water coil
Use of external control
Use of RPM compensation
Filter time
Heating temperature
compensation
EEV stop step in heating
option
installation option 1
installation option 2
Use of discharge
temperature control
Cooling discharge temperature
Heating discharge temperature
Cooling discharge temperature
Heating discharge temperature
Use of humidification when
Heating thermo off
Use of fan operation in Defrost
Use of humidification when Heating
Cooling
Heating
Set temperature
Set temperature difference
EEV control for ERV Plus
checking
checking
Mode master indoor unit
checking
Mode master indoor unit setting
Data
Factory
Description
bit
setting
1,2,3
-
Room temperature
1,2,3
-
1,2,3
-
1,2,3
-
EEV step
1
-
0 – No use, 1 - Use
2
-
0 – No use, 1 - Use
3
-
0 – No use, 1 - Use
4
-
0 – No use, 1 - Use
1
-
0 – No use, 1 - Use
2
-
0 – No use, 1 - Use
3
-
0 – 2000 hours, 1 – 1000 hours
4
-
0-2 °C, 1-5 °C
5
-
12
-
34
-
56
-
Group address (00H~FEH)
1)*
-
Refer to the installation manual
1)*
-
1)*
-
MCU address (00 to 15)
1,2,4
-
3,4
-
0~31 steps
6
-
0 – 30, 1 - 40, 2 - 50
1
-
0 – No use, 1 - Use
3,4
-
8~25 °C (46~77 °F)
5,6
-
18~43 °C (64~109 °F)
1,2
-
13~25 °C (55.4~77 °F)
3,4
-
18~30 °C (64~86 °F)
1
-
0 – No use, 1 - Use
2
-
0 – No use, 1 - Use
3
-
0 – No use, 1 - Use
4
-
0 – No use, 1 - Use
1,2
-
15~30 °C (59~86 °F)
3,4
-
15~30 °C (59~86 °F)
1,2
-
15~30 °C (59~86 °F)
3,4
-
5~15 °C (41~59 °F)
1,2
-
0~10 °C
0 – Non use of humidifier
3
-
1,2
-
10~27 steps
3,4
-
10~27 steps
123456
-
address
123456
-
address
123456
-
address
1
-
0-No use, 1-Use, 2-Release
Unit
°C
°C
°C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 step
-
-
1 °C
1 °C
1 °C
1 °C
-
-
-
-
1 °C
1 °C
1 °C
1 °C
1 °C
-
1 step
1 step
-
-
-
-