Operating instructions Contents Refuelling is now charging Basic safety instructions Scope of delivery Technical data Operation for charging an electric vehicle Inspection/maintenance Error messages 20.03.2018 • Version 1.0...
We are delighted that you have chosen the innogy eBox and hope you will be happy as you join us on our common journey: designing the refuelling of the future!
Basic safety instructions This manual contains information on the correct operation of the innogy eBox. The charging box should be operated and handled ac- cording to these operating instructions. The installation instructions contain detailed information on the installation of the product. Fail- ure to comply with these can compromise its function and safety.
The electric vehicle is connected with the innogy eBox via a charging cable for charging. As the operator of the charging box, you may have to inform the user in an appropriate manner about the correct use of charging cables.
Technical data Geometry Dimensions: (H x W x D) 660 x 240 x 150 mm Installation: Wall mounting Weight: innogy eBox: approx. 5 kg Protection class IP54 Temperature range − 25 °C to + 40 °C Grid connection Power supply:...
Operation for charging an electric vehicle Prerequisite for charging with the innogy eBox is the activation of a vehicle on the innogy eBox. The user of the innogy eBox can avail of the operating modes described below. Operating modes 1. Off 2.
Page 9
The following information is provided for the safe laying of cables for the charging of electric Conduct in case of accidents, fi rst aid vehicles on the innogy eBox. The user of the • Switch off the power. eBox is responsible for the safe handling of •...
Inspection/maintenance The eBox is maintenance-free. It is recommend- ed that an electrician conduct a cyclic inspection of the pre-installation and eBox to the degree stipulated in DIN VDE 0702. An inspection of the pre-installation in accordance with legal and normative requirements, in particular regulatory examination of the function of the residual current device (RCD), is necessary in this case.
Operating instructions Error messages LED fl ashes red 2 x per second: LED fl ashes rapidly green 5 x per second: The charging plug lock is faulty. The vehicle signals invalid current values. • Please check the charging plug (e.g. for dirt). •...
Page 12
SE Flamingoweg 1 44139 Dortmund Germany emobility@innogy.com innogy.com/emobility...