  • Page 1 VE1500A-Ti Fire Truck Loading Pump 《Pump Installation Manual for Fire Truck》 TOHATSU CORPORATION 003-25011-0AH0 181115...
  • Page 2 Copyright © 2018 Tohatsu Corporation. All rights reserved. No part of this manual may be reproduced or transmitted in any from or by any means without the express written permission of Tohatsu Corporation.
  • Page 3: Table Of Contents

    CONTENTS COMPONENT PARTS…...…..…..….…...……...…1 OPERATION PANEL SWITCH AND LAMP..….…..…2 REMOTE PANEL ID……..………….....……...…3 4 EXTERNAL VIEW……..……..…..…..…..…..…..5 VE1500A-Ti……...…………..………………….5 REMOTE PANEL..………..……………………6 5 ACTUAL WIRING DIAGRAM….……………..…..7 6 WIRING DIAGRAM……………………..…………..8 VE1500A-Ti………………..…………………….8 REMOTE PANEL………………….….………...9...
  • Page 4: Component Parts

    COMPONENT PARTS Part No. Appearance Part name Part No. Remarks shape panel panels panels Pump (VE1500A-Ti) Remote 6G8-42020-0 panel 185-42070-0 Connectwire ☆ ☆ ☆ 185-42087-0 harness Straight ☆ ☆ ☆ 6F5-42070-0 185-42078-0 Assistwire harness 15 m 185-42085-0 Instruction 6G8-38317-0 label...
  • Page 5: Operation Panel Switch And Lamp

    OPERATION PANEL SWITCH AND LAMP Remote panel Pump panel ⑬ ⑭ ③ ⑥ ⑦ ⑱ ⑬ ⑧ ⑪ ⑨ ⑩ ⑬ ① ③ ⑭ ② ⑤ ⑧ ⑨ ⑩ ⑮ ⑯ ⑫ ⑰ ⑮ ④ ⑯ ⑪ ⑦ ⑥ Engine running status lamp ①...
  • Page 6: Remote Panel Id

    REMOTE PANEL ID ● Necessity of ID When connecting multiple remote panels, it is necessary to allocate different ID to each remote panel so that signal interference does not occur. The ID for factory shipment is set as follows. Case of 1 remote panel 2 remote panels 3 remote panels...
  • Page 7 REMOTE PANEL ID 2. When releasing the simultaneous press, the current ID is displayed. (ID: 1 to 3). ID:01 ID:02 ID:03 3. To change the ID number, Press "+" or "-" switch of the panel. Select the ID not to overlap among remote panels. ID:01 ID:02 ID:03...
  • Page 8: External View

    EXTERNAL VIEW VE1500A-Ti...
  • Page 9: Remote Panel

    REMOTE PANEL...
  • Page 10: Actual Wiring Diagram

    ACUTUAL WIRING DIAGRAM...
  • Page 11: Wiring Diagram

    WIRING DIAGRAM VE1500A-Ti Ignition coil output LED1(OH)output Exciter coil(H) Injector power supply Exciter coil(L) MAP (atmospheric pressure sensor) input Sensor Power(+) Pulsar coil Pulsar GND Serial communication ECU power supply Boot mode switch FFP output Injector # 1 output Injector # 2 output...
  • Page 12: Remote Panel

    WIRING DIAGRAM REMOTE PANEL...
  • Page 13 VE1500A-Ti Fire Truck Loading Pump 《Pump Installation Manual for Fire Truck》 TOHATSU CORPORATION Address : 3-5-4 Azusawa, Itabashi-ku, Tokyo, JAPAN : +81-3-3966-2951 Overseas section fire protection sales department Phone : +81-3-3966-3137 Email bousaiex@tohatsu.co.jp TOHATSU CORPORATION 003-25011-0AH0 181121...