Download Print this page

Device Information - Dimplex HPK 200S Installation And Operating Instructions Manual

Hydraulic tower with hpm

Advertisement

Available languages

Available languages

11

11 Device information

1
Type and order code
2
Design
2.1
Model
2.2
Protection type according to EN 60529
2.3
Installation location
3
Technical data
3.1
Heat generation
3.2
Heat consumer
Unmixed heating circuit with electronic circulating pump
Mixed heating circuit with electronic circulating pump
Domestic hot water preparation (adjacent tank)
3.3
Buffer tank
3.4
Diaphragm expansion vessel
Volume/admission pressure
Connection for additional expansion vessel
3.5
Start-to-leak pressure safety valve
3.6
max. operating overpressure
3.7
max. operating temperature
3.8
electrical pipe heater
Immersion heater
3.9
Sound power level
3.10 Sound pressure level at a distance of 1 m
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heat generator
4.3
Device connections to unmixed heating system
4.4
Device connections to mixed heating system (optional)
4.5
Device connections to domestic hot water
4.6
Weight of the transportable unit(s) incl. Packing
5
Electrical connection
5.1
Fuse protection control voltage
5.2
Fuse protection load voltage (2nd heat generator 6 kW)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Regulator internal/external
1. Optionally, the hydraulic module can be expanded by a heating circuit with three-way mixer. The components required for this setup are available as an expansion set.
2. The standard equipment of the hydraulic module contains a pump adapter (inside micrometer 180 mm; 1-1/2") as well as shut-offs for the subsequent installation of a hot water
charge pump for an adjacent hot water tank.
3. Note that additional space is required for pipe connections, operation and maintenance.
4. See CE declaration of conformity
5. The heat circulating pump and the heat pump controller must always be ready for operation.
EN-6
litres
litres / bar
bar
bar
°C
kW
kW
dB(A)
dB(A)
3
H x W x L mm
Inch
Inch
Inch
Inch
kg
230 V [AT]
230 V / 400 V [A]
5
HPK 200S
Hydraulic tower with dual differential pressureless manifold
IP 20
Indoors
External
Yes
Optionally available
Optionally available
210
24 / 1,5
1" external thread
2,5
2,0
85
2, 4 or 6
up to 6 (optional)
37
31
1660 x 680 x 775
1 1/4" external thread
1 1/4" external thread
1 1/4" external thread
1 1/4" external thread
187
10
32 / 16
4
Yes
Internal
1
2

Advertisement

loading