Troubleshooting
Trouble
Remedy
Unit will not run.
• Raise humidistat setting
• Check 120 volt power source
• Free float from obstruction
Unit will not shut off.
Unit will not dry out
completely
I Bottles continue to
empty.
Unit is not emptying.
Unit runs and shuts
off before bottles are
empty
Probable
Cause
• Humidity level is too high
• No power
• Float is not free
• Water is present in the
system
• High humidity or low
temperature
resulting in
slow evaporation
• Air is entering water reser-
voirs.
• Dirty filter
• Reservoir
cap plunger
missing post in bottom of
cabinet.
! • Humidity
level is too high
• Unit is not setup on a level
surface (Float will not
sense water at the rear of
the cabinet.
• This is normal. A small
amount of water remains in
the cabinet.
• Allow unit to continue
opera-
tion.
• Check "E-Z-Fill Side-Caps" to
ensure tightness.
• Check for leak in water bottles.
• Are gaskets for "E-Z-Fill Side-
Caps" in place (see repair
parts list).
• Change
to a fresh new filter.
• Check orientation
of bottle.
Reposition
so that reservoir
cap plunger
is depressed
by
post in bottom of cabinet.
• Raise humidistat
setting (if
possible)
• Position
unit level (Some car-
pet padding
may allow unit to
set lower in the front than the
rear with the additional
weight
of water bottles in the front of
the cabinet.
Install coasters
under front casters.
CAUTION:
Use only 42-14900
EPA Registered
Bactedostat
available
from
Sears Retail store.
Use of other water treatment
products
may damage the filter elements.
Under no circumstances
should
you use water treatment
products
designed
for Roto belt or Ultrasonic
humidifiers.
13