(APPLY THIS LABEL WHERE EASILY SEEN)
Cleaning frequency is dependent upon mineral content of water supply.
Check every other week until schedule can be determined.
1. Turn humidistat to "minimum
setting."
2.
Disconnect
water at humidifier
using quick
disconnect.
3.
Remove
front panel,
remove
overflow
tubing
(if used),
slide out reservoir
and media
wheel assembly
while
raising
latch on right hand side.
4.
Lift out media wheel
by flexing
wire support
outward
to release
shaft.
5.
Pull out pivot pin, remove
float and arm.
6.
Empty water from reservoir.
7.
Lift out reservoir
liner and replace
(part number
215711-01),
or clean.
8.
Clean
residue
and lime build-up
from all parts using a solution
of vinegar
and water,
detergent
and
water,
or Sears All-Purpose
Humidifier
Cleaner
(stock
number
42-14713).
9.
Remove
media
pad from wheel
and clean thoroughly;
replace
pad if necessary
- available
from Sears
(stock
number
42-9335).
IMPORTANT:
Stretch
new pad lengthwise
before
placing
in wheel.
10. If the reservoir
has been overflowing
the float valve
button
may be worn.
Remove
float valve button,
turn over and reinsert
or replace
if both surfaces
are worn.
(Part Number
281101-01)
11. Reassemble
parts in reservoir
(Flex wire support
outward
to capture
media wheel
shaft
under
dimples)
and slide back into humidifier.
Engage
latch on right hand side with float valve stem.
12. Attach
water
supply
quick connect,
attach
overflow
tubing
(if used), and allow
reservoir
to fill.
13. Check water
level and adjust
float if required.
14. Turn humidistat
to "test"
momentarily
and check for media wheel
rotation.
Reset
humidistat
according
to outdoor
temperature
as instructed
on label and reinstall
front cover.
Unit is back in
operation.
Summer
Shutdown
Unplug
transformer,
close saddle
valve, close bypass
damper.
Clean per above and leave
reservoir
empty.
(As
a reminder
you may want to put a tag or sticker
on the unit indicating
it has
been shutdown
and will require
startup
in the fall.)
Fall Startup
Plug in transformer,
open saddle
valve,
open bypass
damper
and set humidistat
to "test".
Check for
proper
water
level and media
wheel
operation.
Reset
humidistat
according
to the outdoor
temperature
as
instructed
on label.
Unit is back in operation.
PIN 21604001R10-00