Format Command Execution Time For 512-Byte Sectors (Minutes); General Performance Characteristics; Start/Stop Time - Seagate SAVVIO ST9300405SS Product Manual

Serial attached scsi disc drives
Hide thumbs Also See for SAVVIO ST9300405SS:
Table of Contents

Advertisement

5.2.2

Format command execution time for 512-byte sectors (minutes)

Maximum (with verify)
Maximum (without verify)
Note.
There is approximately a 1.5 increase in time to format a SED drive versus a non-SED drive of the same capacity.
5.2.3

General performance characteristics

Minimum sector interleave
Data buffer to/from disc media (one 512-byte logical block)*
Sustained transfer rate
SAS Interface maximum instantaneous transfer rate
Logical block sizes
512 (default), 520, 524 or 528.
Read/write consecutive sectors on a track
Flaw reallocation performance impact (for flaws reallocated at format time using the
spare sectors per sparing zone reallocation scheme.)
Average rotational latency
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or
from the host.
** MiB/s x 1.048 = MB/s
5.3

Start/stop time

The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has
been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30
seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1.
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the
drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does
not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT
command.
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 sec-
onds (maximum) from removal of DC power. SCSI stop time is 20 seconds. There is no power control switch
on the drive.
10
900GB
600GB
234
156
116
75
450GB
117
58
1 to 1
1.00 to 1.91 Gb/s
89 to 160 MiB/s **
93 to 168 MB/s
600 MB/s* per port
(dual port = 1200 MB/s*)
Yes
Negligible
3.0ms
Savvio 10K.5 SAS Product Manual, Rev. D
300GB
78
36

Advertisement

Table of Contents
loading

Table of Contents