Download Print this page

LAUNCH TECH Millennium 40 Quick Start Manual page 2

Advertisement

40 50/60
2. Basic Operations
The icons in black at the bottom of
the screen indicate the available
actions, which can be done by
pressing the corresponding buttons
on the tool.
Read DTC
Press the F1/DTC button to retrieve
Ÿ
the DTC.
Press the F4/
button to get more
Ÿ
?
details about the DTC.
If more than one DTC was retrieved,
Ÿ
press
/
to view different DTCs.
In the case of long code definitions,
Ÿ
use
/
to view the additional
information.
Erase DTCs
Once DTCs have been retrieved,
press the F2/ER button to erase.
Check I/M Readiness
Press the F3/I/M button to check the
I/M(Inspection & Maintenance)
readiness.
/
Quick Start Guide
Monitor Status
MIL Status
DTCs in this ECU
Readiness Completed
Readiness Not Completed
Readiness Not Supported
Datastream Supported
Ignition
Protocol Type
?
DTC
C138F
GM
The fault code is not found in the database
?
Erase Codes
Clear/Reset Emission-Related Diagnostic
Information. Are you sure?
?
I/M Readiness
Misfire Monitor
Fuel system
component monitor
Catalyst monitor
3. Register & Update
The tool can be updated via USB cable.
OFF
Note: Make sure the PC has an Internet connection.
108
5
1. Go to
www.dbscar.com
2
3
computer.
119
2. Decompress and install it on your computer(compatible with
Spark
CAN
Windows XP, Windows 7, Windows 8 & Windows 10).
3. After installation, connect one end of the USB cable to the
USB port of PC, and the other end to the tool.
4. If a newer version is found, a
1/13
screen similar to Fig. A will
Pending
appear.
5. Launch the update tool on
your PC, Fig. B will appear.
6. Choose the desired interface
language and then click [Device
Update] to enter update center.
Select Language
Product Serial Number
7. Choose the software version and then click [Update] to start
N/A
updating.
OK
8. Once update is complete, a "Upgrade success" message
INC
box will pop up.
N/A
9. The update process is complete, your tool is now ready for
use.
1~ 4/10
and download the update tool to the
Boot Version:
V1.00.000
Serial Number:
972890000029
Register Code:
36FFDB054753
1. USB Connected for Upgrade.
2. Press [EXIT] key to Enter
Normal Mode.
B
English
Device Upgrade
A

Advertisement

loading

This manual is also suitable for:

Millennium 60Millennium 50