Operation
Main Menu
From the Home screen, press the Menu button to enter
the Main menu, where you can choose to see machine
information, make setup changes, set the Energy Saver
mode, or enter the Service Menu.
Machine Info Menu
From the Main menu, ensure that Machine Info is
highlighted and press the Checkmark to view a list
including capacity, model number, Ice Machine Head
serial number, condenser serial number, warranty,
installation date, date of manufacture and software
version. Use the Down arrow to highlight an item and
use the Checkmark to view the information. Press the
Left arrow to return to previous screens.
Password Entry
A password is not required, although a password can be
turned on to prevent unauthorized control setting
modification. You can use the Factory Default Password
of "1234" or enter a four digit custom pin number of your
choosing.
To turn on the password feature use the following
procedure.
1. Press the Menu button.
2. From the Main menu, use the Down arrow to
highlight setup and press the Right arrow.
3. Use the Down arrow to highlight Password ON and
press the Right arrow.
4. Press the Right arrow again with Enter Passwrd
highlighted and an icon will flash.
5. Use the Up & Down arrows to enter the factory
password (1, 2, 3, 4). Enter the number 1 in the
flashing icon (first digit of the factory password).
6. Press the right arrow to move to the next cell and
use the Up & Down arrows to add the number 2.
Repeat this process to add 3 & 4.
7. When the last number is entered press the
Checkmark button to save your entry..
E n t e r P a s s w r d
[
E x i t
30
To enter a four digit password of your choosing use
the following procedure.
1. Press the Menu button.
2. From the Main menu, use the Down arrow to
3. Use the Down arrow to select Edit Password and
4. Using the Up & Down arrows, enter the first digit of
5. Press the right arrow to move to the next cell and
6. When the last number is entered press the
7. Follow steps 4 & 5 and enter your 4 digit password.
8. When the last number is entered press the
RESET PASSWORD TO FACTORY DEFAULTS
The password can be reset to the factory defaults when
required. The default factory password is 1234. To reset
the ice machine to factory defaults use the following
procedure.
1. Press the Menu button.
2. From the Main menu, use the Down arrow to
3. Press the Checkmark button two times to reset the
]
>
LuminIce Bulb Minder
highlight Setup and press the Right arrow.
press the Right arrow.
the factory password in the flashing icon.
use the Up & Down arrows to add the number 2.
Repeat this process to add 3 & 4.
Checkmark button.
Checkmark button to save your entry.
highlight Fact Deflts
ice machine. The display will return to the Set-Up
menu and the defaults listed below will be in effect.
Refer to Setup to adjust settings.
Setting
Language
Time/Date
Month/Day/Year/Time
Time Configuration
Units
Fahrenheit/Lbs/Gallons
Ice Clarity
LCD Brightness
Password On
Default Password = 1234
Edit Password
Clean Minder
AuCS RunTime
Air Filter Minder
Water Filter Minder
Ice Bin Sensor
Section 3
Default
English
Mo/Day/Yr/24 Hour
Off
Level 2
Off - Enter Password
Off - Edit Password
Off
Off
Off
Off
No
Off
Part Number 000007924 5/14