If a problem does occur, check the following:
PROBLEM
No Meter Reading
(AC Cord Unplugged)
Charger will not turn
on when properly connected.
Clicking noise from charger.

TROUBLESHOOTING

POSSIBLE CAUSE
Clips are not making
a good connection.
Battery voltage is too low.
2 amp charge rate being used.
AC outlet is dead.
Poor electrical connection.
Circuit breaker is cycling.
Battery is defective.
Severely discharged battery
but otherwise a good battery.
Reverse connections at battery.
10
SOLUTION
Rock clips back and forth for a better
connection.
Plug AC line into outlet.
Meter should now indicate.
None, meter will not indicate here.
Plug in a lamp to check for voltage.
Check connections, rock back and forth
for a better connection.
May be in the wrong switch position
Have Battery checked.
Allow charging to continue until battery has a
chance to recover sufficiently to take a charge.
If more than 20 min. stop charging and have
the battery checked.
Shut off charger and correct lead connections.