Page 1
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual...
Page 2
I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 Part 1 (series) Part 2 (Size) Part 3 (Oupt) Part 4 (AUX) I. Model Code Symbol 1. (Part 1) Basal function of instrument AI-208, standard temperature controller 0.3%FS±1℃...
3. (Part 3 and 4) indicate the module installed in OUTP and AUX sockets. Allowed modules in each socket are as below: Allowed Type Module Socket √ √ 3. OUTP (main output) √ √ √ 4. AUX (Auxiliary output) (or none) no module installed Relay contact output module (Capacity: 5A/250VAC and 5A/30VDC, normal open terminal can absorb spark) Relay contact output module (Capacity: 2A/250VAC, small volume)
III. FRONT PANEL AND OPERATION Process Value(PV), or parameter code ① ① ② Set Value(SV), alarming code, or value of a parameter Setup key, for accessing parameter table, and confirming change. ③ Data shift key, also for activating auto turning ④...
Page 5
V. PARAMETER AND SETTING Field parameter table (Press and hold for 2 seconds to access) Code Name Description Setting Range Alarm on when PV (Process Value) >HIA; High limit alarm 0~999℃ alarm off when PV<HIA-AHY Lower Limit Alarm on when PV (Process Value) < LoA; 0~999℃...
Page 6
The value of FIL will determine the ability of filtering noise. When a large value is set, the measurement input is stabilized but the response speed is slow. Generally, it can be set to 1 to 3. If great interference exists, then you can increase parameter “FIL” PV input filter 0~40 gradually to make momentary fluctuation of measured value less than...
Page 7
Wiring graph for D2 dimension(48X48mm)instruments: 100-240VAC~ Main Output OUTP Alarm Output...