1. Introduction This meter has been designed and tested in accordance with the CE safety requirements for electronic measuring apparatus, EN 61010-1, IEC 61557-1, IEC 61557-2 and other safety standards. Follow all warnings to ensure safe operation.
----- BESANTEK 2. Safety Notes • Read tne following safety infonnation carefully before attempting to operate or service tne meter. • Use tne meter only as specified in tnis manual; otnerwise the protection proVided by tne meter may be impaired.
3. Feature ● Microprocessor controlled. ● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V ● The maximum insulation measurement range is 200G ohm @1000V. ● 1mA test current on insulation test at nominal voltage. ● Large LCD (78 × 67mm). ●...
----- BESANTEK 6. Measuring Methods & OPERATION CAUTION Observe all safety precautions wllen you select 125V, 250V, 500V or 1 000V position. Connect tile meter test leads to tile circuit under test before operating tile "TEST'' button. Do not touch the clip ends of the test leads wllen the "TEST'' button is pressed.
Page 10
----- BESANTEK (1) Insulation Resistance Test: & warning Insulation tests should be conducted on circuits that are de-energised. Ensure circuits are not live before commencing testing. a. Select the required test voltage (125V, 250V, 500V, 1000V) by rotating the function switch.
Page 11
(3) Voltage test : a. Select the "600V" or "2000mV" range by rotating the function switch. b. Connect test leads to circuit being measured. c. Read the value of voltage from the LCD. ※ 600V : AC/DC automatically detection. 2000mV : AC/DC "Select" cutover. (4) Capactance test : a.
----- BESANTEK 7. Maintenance &caution Always disconnect the test leads from instrument before batteries or fuse replacement. • Batteries Replacement: Please replace batteries when the • � " indicator was shown on the LCD. Disconnect the test leads from the instrument, remove the battery compartment lid and the batteries.
Page 13
----- BESANTEK &WARNING To avoid electrical shOcl< or damage to the meter, do not get water inside tne case. 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com -11-...