HDL-MP8B-RF.18
Max Level
The max output brightness of a channel.
For channel1, if the connected load is bulb, the max value cannot exceed 80%; if the
connected load is LED, the max value must be small (less than 80%, user needs to test
the proper value themselves), otherwise power interface cannot supply enough power,
then lead to dimming flicker, more serious, the power interface will automatically restart.
If the connected load is LED, and its power is less than 30W, must connect the constant
current module in parallel, the max value can up to 80%.
Test Level, Set and output
Input the test level, check the box to turn on the channel, un-check to turn off it. It's used to
test the loads after installation.

6.4 Dimmer Setting

Dimmer Turnoff Temperature
Set the temperature for protection, when the panel's detected temperature reaches to the
setting temperature, it will turn off the connected loads automatically. When the detected
temperature is lower than the setting temperature, it will restore the loads' status again.
Dimmer brightness save
It can restore the 'channels' status before power off'.
Save: Save the channels' statuses which have lasted for at least 20 seconds before
power failure, and restore the status when power on.
Don't save: Do not save the channels' statuses before power failure, and all channels will
OFF when power on.
Dimmer Address Information
The connected power interfaces' status shows "Occupied", and the unconnected shows
"Free". The panel will assign the dimmer address 1-4 for the connected power interfaces