Technical Data - Triax GNS 20 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

technical Data

type
order No.
Frequency range
Input 1 - UHF (1)
Input 2 - VHF III
Input 3 - VHF I
- UHF (2)
Input 4 - FM
- VHF I
option: input 1 and input 2
combined with jumper
Gain *
Input 1 - UHF (1)
Input 2 - VHF III
Input 3 - VHF I
- UHF (2)
Input 4 - FM / VHF I
Level controller
at all inputs
Noise figure *
Input 1 - UHF (1)
Input 2 - VHF III
Input 3 - VHF I
- UHF (2)
Input 4 - FM / VHF I
output level, iMR = 60 dB *
IMR 3 acc. EN 50083-5
IMR 2 acc. EN 50083-3
Power supply
Supply voltage (50 - 60 Hz)
Power consumption
Ambient conditions acc. EN 60065
Operating temperatur range
Degree of protection
Protection class
MTBF (Belcore @ 25°C)
housing
Weight
Dimensions W x H x D
HF connections 75 O
Screening
acc. EN 50083-2
* Level controller 0 dB
tRiAX A/S
Bjørnkærvej 3
DK-8783 Hornsyld
triax.com/support
Phone: +45 76 822 200
Fax: +45 75 687 966
www.triax.com
8
Copyright © 2016 TRIAX. All rights reserved. The TRIAX Logo and TRIAX, TRIAX Multimedia
are registered trademarks or trademarks of the TRIAX Company or its affiliates.
All specifications in this guide are subject to change without further notice.
TRIAX A/S | Bjørnkærvej 3 | DK-8783 Hornsyld | Denmark
GNS 20
339120
MHz
470...862
MHz
174...230
MHz
-
MHz
-
MHz
47...68 and
MHz
87,5...108
MHz
470...862 and
174...230
dB
22
dB
20
dB
-
dB
-
dB
20
dB
0...-20
dB
4
dB
4
dB
-
dB
-
dB
4
dBµV
113
dBµV
102
V~
230 ±10%
W
3,5
°C
–25 ... +55
II, isolated guard
IP 20
h
300.000
kg
ca. 0.68
mm
150 x 80 x 50
F connectors
class A
GNS 30
339130
470...862
174...230
47...68
-
-
87,5...108
470...862 and
174...230
31
30
30
-
30
0...-20
4
4
4
-
4
115
105
230 ±10%
6
–25 ... +55
II, isolated guard
IP 20
300.000
ca. 0.68
150 x 80 x 50
F connectors
class A