Symptom
Vacuum will not operate
Dust comes from motor cover.
Reduced efficiency and motor/
speed vibration.
TROUBLESHOOTING
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Collection tank full.
1) The reusable cloth filter is
missing or damaged.
1) There is a blockage in the
nozzle or hose, or the
collection tank inlet. Or dust
filter blocked by fine dust.
Corrective Action
1) Check power supply – cord,
2) Unplug and check the
3) Empty collection tank.
1) Attach or replace the
1) Check nozzle, hose and
13
breakers, fuses.
power cord. If damaged,
have it repaired by a
professional.
reusable cloth filter.
collection tank inlets for
blockage. Take off the filter
and clean it or install a new
filter.