Method C: Insertion Systems; Specific Module Ranges - Canadian Solar CS6P-PE Installation Manual

Solar module
Hide thumbs Also See for CS6P-PE:
Table of Contents

Advertisement

A2
A2
Support bar
Authorized range for clamping as a function of model type: 
Model type 
A1 range (mm) 
CS5A 
220 – 380 
CS5AH 
120 – 170 
CS5P 
220 – 390 
CS6A 
220 – 340 
CS6P, CS5T 
240 – 410 
CS6X 
340 – 550 
CS6V 
240 – 410 
CS6VH 
130 – 210 
 
6.3    METHOD C: INSERTION SYSTEMS 
The mounting method has been qualified by Canadian Solar Inc and certified by VDE. 
Insertion methods will vary and are dependent on the mounting structures. Follow mounting guidelines recommended 
by the mounting system supplier. 
Each module must be securely maintained through all its length on two opposite sides. Install and tighten the insertion 
profiles  to  the  support  structure  using  the  hardware  and  instructions  provided  by  the  mounting  system  manufacturer. 
System designer and installer are responsible for load calculations and for proper design of support structure.   
Canadian Solar Inc. warranty may be void in cases where improper insertion systems or unsuitable installation methods 
are found. When installing insertion profiles, take measures so as: 
1. Not to bend the module frame 
2. Not to touch or cast shadow on the front glass 
3. Not to damage the surface of the frame 
4. To ensure the insertion profiles overlap the module frame by at least 10 mm. 
5. To  ensure  the  module  frame  (C‐shape)  overlap  the  insertion  profiles  by  at 
least 15mm. 
6. To  ensure  insertion  profile  thickness  and  tolerances  suits  module thickness 
(40mm for most of Canadian Solar inc modules). 
 
 
 
 
 
www.canadiansolar.com
A2
A2
 
B1 range (mm) 
A2 range (mm) 
330 – 400 
170 – 200 
120 – 170 
170 – 200 
330 – 400 
220 – 270 
270 – 330 
200 – 250 
340 – 410 
200 – 250 
410 – 490 
200 – 250 
340 – 410 
170 – 210 
160 – 210 
170 – 210 
 
EN-Rev 2.4 Copyright© May 2013.CanadianSolarInc.
 
Downforce load ≤ 2400 Pa
Insertion 
profile on 
long side 
frame 
For CS6X series, installations where the downforce load can reach up to a 5400Pa are authorized. 
Use 2 insertion profiles running parallel to the short 
Insertion 
profile on 
For CS5P and CS6P series, an additional support bar 
short side 
should be placed below the module where download 
frame 
force above 1600Pa is expected. 
 
6.4    SPECIFIC MODULE RANGES 
Technical notes 
For  SunTuile  module  frames  (SunTuile  series:  CS5A‐xxxMF  and  CS6A‐xxxPF  models),  please  refer  to  the  most  updated 
IM/IEC/ SUNT‐EN technical note. 
For NewEdge module frames (NewEdge series: CS5A‐xxxMX and CS6P‐xxxPX models), please refer to the most updated 
IM/IEC/ NEWE‐EN technical note. 
For  frameless  laminates  (CS5A‐xxxM‐L  model)  mounted  with  Intrasole  CL,  please  refer  to  the  most  updated 
IM/IEC/INTCL‐EN technical note. 
Floating clamped configuration (only for CS5A‐M‐L laminate model) 
Clamping methods will vary and are dependent on the mounting structures. Follow mounting guidelines recommended 
by the mounting system supplier. 
Each laminate must be securely fastened at a minimum of 8 points on the two opposite long sides. Clamp positions are of 
crucial importance for the reliability of the installation, the clamp centerlines must only be positioned within the ranges 
www.canadiansolar.com
10
Table 5: Authorized attachments for insertion method 
Uplift load ≤ 2400 Pa 
 
2400 Pa ≤ Downforce load ≤ 4000 Pa 
Use 2 insertion profiles running parallel to the long side frame. 
 
Use 2 insertion profiles running parallel to the short 
side frame.   
 
An additional support bar should be placed below 
For CS6X series, installations where the downforce 
load can reach up to a 5400Pa are authorized 
 
EN-Rev 2.4 Copyright© May 2013.CanadianSolarInc.
Uplift load ≤ 2400 Pa 
 
side frame.     
 
the module. 