Arming The System - Scantronic 9600 User Manual

Microprocessor intruder alarm control panel
Hide thumbs Also See for 9600:
Table of Contents

Advertisement

A
Note 1
if display shows
INVALID CODE YES/
NO press the 'Yes' or
'No' key and re-enter
your access code.
Note 2
When selecting groups
to be armed, select
Group 'A' for Full Set
or select group 'B', 'C'
or 'D' for Part Set.
Note 3
The zones set when the
user selects Group 'B',
'C', or 'D' are pro-
grammed by the engineer.
(See Page 22)
Note 4
If the system has been
programmed for and
fitted with an Exit lock,
the system will set when
the final door has been
closed and the lock has
been operated. The exit
tone will automatically be
terminated.
T
S
RMING
HE
YSTEM
00:01 MON 01 JAN
Key-in valid
Access Code
ENTER CODE
****
SET SYSTEM?
Press Yes
SELECT AREA
Key-in group to be
set. See Note 1
OMIT ZONES?
Press No
LEAVE AREA
Sounder emits
continuous tone
Leave the premises via the
prescribed exit route. The
alarm system will
automatically set on expiry
of the exit timer or closing of
the final door, or pressing
the exit terminate button.
(See Notes 3 & 4 )
SYSTEM SET
00:01 MON 01 JAN
2
Note 5
If the system has been
programmed for 'Instant
Set' it will set instantly
and silently when the user
enters a valid code and
there are no faults
present. If faults exist, the
keypad will emit a single
error beep and cycle
through any faults for the
duration of the pro-
grammed exit time and
then return to the day
state. Check for faults as
necessary.
3

Advertisement

Table of Contents
loading

Table of Contents