Scantronic 9600 User Manual
Scantronic 9600 User Manual

Scantronic 9600 User Manual

Microprocessor intruder alarm control panel
Hide thumbs Also See for 9600:

Advertisement

Microprocessor
Intruder
Alarm
Control
Panel
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Scantronic 9600

  • Page 1 Microprocessor Intruder Alarm Control Panel User Manual...
  • Page 2: Table Of Contents

    ONTENTS Section Title Page INTRODUCTION....................1 ARMING THE SYSTEM..................3 ARMING WITH OPEN/FAULTY ZONES............4 SETTING WITH CIRCUITS OMITTED............5 DISARMING THE SYSTEM................6 ARMING/DISARMING BLOCK OMIT GROUP D.......... 7 DISARMING AFTER ALARM CONDITION........... 8 DAYTIME TAMPER ALARM.........
  • Page 3: Introduction

    NTRODUCTION The 9610 Microprocessor Intruder Alarm is a fully programmable system. Your system will have been programmed by your alarm company engineer for the func- tions and options specified at installation. Access to the various user functions is divided into two user levels, determined by the access code.
  • Page 4 NTRODUCTION (Cont.) Holiday Codes A 'Holiday' access code can be given to a relative or a person looking after the property while you are on holiday. The 'Holiday Code' is programmed by someone with 'Manager' authority. As soon as the 'Holiday' code is programmed, the system must be armed and disarmed using this access code.
  • Page 5: Arming The System

    RMING YSTEM Note 1 00:01 MON 01 JAN if display shows INVALID CODE YES/ NO press the 'Yes' or Key-in valid 'No' key and re-enter Access Code your access code. ENTER CODE **** SET SYSTEM? Note 2 When selecting groups to be armed, select Press Yes Group 'A' for Full Set...
  • Page 6: Arming With Open/Faulty Zones

    RMING AULTY ONES 00:01 MON 01 JAN Note 1 Key-In valid if display shows Access Code INVALID CODE YES/ NO press the 'Yes' or ENTER CODE 'No' key and re-enter **** your access code. SET SYSTEM? Press Yes Note 2 When selecting groups to be Key-in group to be armed, select Group 'A' for...
  • Page 7: Setting With Circuits Omitted

    ETTING IRCUITS MITTED 00:01 MON 01 JAN Key-In valid Note 1 if display shows Access Code INVALID CODE YES/ NO press the 'Yes' or ENTER CODE 'No' key and re-enter **** your access code. SET SYSTEM? Note 2 Press Yes Only circuits programmed by the engineer as 'Omit SELECT AREA...
  • Page 8: Disarming The System

    ISARMING YSTEM Enter the premises Note 1 via the prescribed if display shows entry route INVALID CODE YES/ NO press the 'Yes' or 'No' key and re-enter Entry tone starts your access code. (interrupted tone) 1st Ply timer - See Notes Key-in your Access Code at the nearest keypad...
  • Page 9: Arming/Disarming Block Omit Group D

    RMING ISARMING LOCK ROUP Disarming Group 'D' Block Omit Enter the premises via the prescribed Entry Route Note 1 if display shows INVALID CODE YES/NO Entry tone starts press the 'Yes' or 'No' key and re-enter your access code. Key-in your 'Block Omit Code' at the Note 2 nearest keypad...
  • Page 10: Disarming After Alarm Condition

    ISARMING FTER LARM ONDITION Enter the premises via the prescribed entry route Entry tone starts Key-in your Access Code at the nearest Note 1 keypad if display shows INVALID CODE YES/ ENTER CODE NO press the 'Yes' or **** 'No' key and re-enter Display will show your access code.
  • Page 11: Daytime Tamper Alarm

    LARM 00:01 MON 01 JAN Internal sounders emit a Note 1 high level warning tone The 9600 system incorporates 24 hour monitoring on all Key-in your Access Code wiring and detection devices. If at the nearest keypad this circuit is violated it will...
  • Page 12: Silent Personal Attack Alarm

    ILENT ERSONAL TTACK LARM 00:01 MON 01 JAN Personal Attack button has been pressed Note 1 If the 'Silent Personal Attack' function has been Silent transmission to the programmed, operating a alarm company central P.A. button will cause the station remote signalling to transmit a signal to the Keypad display shows PA...
  • Page 13: Fire Alarm

    FIRE ALARM Internal sounder generating a Note 1 quick two tone warning, the If the system has smoke or external bell is pulsing and the heat detectors fitted to a external strobe is on. zone which has been programmed as Fire and a Display will show FIRE fire is detected, the zone has been activated...
  • Page 14: Chime Function

    HIME UNCTION Note 1 00:01 MON 01 JAN Only zones which have been programmed by the installation engineer as Key-in a valid 'Chime' zones will operate Access Code this facility. SET SYSTEM? Press No SET OPTIONS? Press Yes Note 2 SET CHIME? Opening a zone which has been programmed as...
  • Page 15: Changing Time And Date

    HANGING MANAGER AUTHORITY ONLY 00:01 MON 01 JAN ENTER MONTH Key-In valid Key-in month e.g., 1=Jan Access Code Press Yes ENTER CODE ENTER DATE **** SET SYSTEM? Key-in date e.g., 1 Press No Press Yes ENTER DAY SET UP OPTIONS MON=1 SUN=7 Press Yes Key-in day e.g., 3= Wed...
  • Page 16: Changing Manager 1 Code

    HANGING ANAGER MANAGER AUTHORITY 00:01 MON 01 JAN ONLY Key-In a manager Note 1 Access Code User 1 Access Code is al- ways the manager. It can- ENTER CODE not have the authority **** changed. SET SYSTEM? Note 2: The system will not Press No SELECT AREA accept a Zero as the first...
  • Page 17: Changing User Code Authority

    HANGING UTHORITY MANAGER AUTHORITY ONLY ENTER NEW CODE CHANGE CODES ?. Press Yes Key-in new 4 digit code (See Note) SELECT USER NO. CHANGE CODES ?. Enter user number e.g., 2 Press No button 3 times to Display shows user code if display time and date previously programmed, also authority...
  • Page 18: Omit 24 Hour Zones

    24 H ONES MANAGER AUTHORITY ONLY OMIT 24 HOUR ZONES REMOVE OMIT 00:01 MON 01 JAN 00:01 MON 01 JAN Key-in a manager Key-in a manager Access Code Access Code SET SYSTEM ? SET SYSTEM ? SYSTEM UNSET Press No Press No SET UP OPTIONS ? SET UP OPTIONS ?
  • Page 19: Bell Test

    Note 1 00:01 MON 01 JAN System will automatically test each warning device for 3 seconds. Key-in a Manager Access Code Note 2 Pressing the 'No' key during the SET SYSTEM ? test, will abort the test. Press No button twice BELL TEST ? Press Yes TESTING...
  • Page 20: System Walk Test

    YSTEM Note 1 00:01 MON JAN This test allows you to test your system. However, you Key-in Manager cannot test any P.A. but- Access Code tons or 24 hour circuits. If you do test these, an SET SYSTEM ? alarm will occur. Press No button 3 times WALK TEST ?
  • Page 21: View Event Log

    VENT RINT 00:01 MON 01 JAN Key-in a valid Access Code SET SYSTEM? Press No button 4 times VIEW LOG? Press Yes The latest event will be the first displayed Note 1 00:01 MON 01 FEB The control panel has ACCESS USER ! an internal log which is capable of logging...
  • Page 22: Display Messages

    ISPLAY ESSAGES Call alarm company engineer to check system. CALL ENGINEER System is unable to reset due to a fault existing. Check as CANNOT RESET necessary or call engineer. User has exceeded the programmed exit time or a fault exists EXIT FAULT with the detection on exit route, check as necessary or call engineer.
  • Page 23 ISPLAY ESSAGES (Cont'd) The load on the AUX 12V supply is excessive and the AUX POWER FAIL protecting fuse has been operated. Contact the installing company to investigate. The battery has become faulty and will not maintain the BATTERY system in the event of a power failure. Contact the FAILED installing company to investigate.
  • Page 24: Your Circuit Description

    IRCUIT ESCRIPTION GROUP OMIT ZONE DESCRIPTION CHIME ALLOWED Installed by (Engineer's signature)......GROUP Date Completed......... ENGINEER RESET......EXIT TIME BELL DURATION......ENTRY TIME COMMUNICATOR FITTED....Note: Group D can be either Part Set or Block Omit depending on the way the system is programmed.
  • Page 25: Service Record

    ERVICE ECORD REPORT DATE...
  • Page 26: Service Contact

    ERVICE ONTACT COMPANY NAME......................ADDRESS............................................................................................................. CONTRACT Nº Service Telephone Number...
  • Page 27 Scantronic Ltd. Perivale Industrial Park, Greenford, Middx. UB6 7RJ.England Tel: 081-991 1133, Telex: 915 810 SCANCO G Fax: 081-997 4448 SCANTRONIC Customer Support (UK) - Tel - (0800) 373767 or (0594) 543343 Pt. No. 496655/ MAY 91/ Issue 1...