Scantronic 9600 User Manual page 23

Microprocessor intruder alarm control panel
Hide thumbs Also See for 9600:
Table of Contents

Advertisement

D
AUX POWER FAIL
BATTERY
FAILED
COMMS FAILED
COMMS LINE FAULT
COMSS SUCCESSFUL
KEYPAD nn TAMPER
LOW BATTERY
SYSTEM INHIBITED
TELEPHONE FAILED
UNIT TAMPER
WATCHDOG FAULT
ZONE TEST FAILED
CALL ENGINEER
M
ISPLAY
ESSAGES (Cont'd)
The load on the AUX 12V supply is excessive and the
protecting fuse has been operated. Contact the installing
company to investigate.
The battery has become faulty and will not maintain the
system in the event of a power failure. Contact the
installing company to investigate.
The system has tried to contact the central station but for some
reason has failed.
Log message corresponding to the TELEPHONE FAILED
message on the display
The central station has successfully acknowledged receipt of a
communication.
Either the wiring to keypad nn has been cut or the keypad back
tamper switch has been opened. If the system is programmed
for customer reset then correct the fault and reset the system.
If not, contact the installing company.
The battery voltage is at a seriously low level. Mains power
must be restored to the system in the near future otherwise the
system will fail completely.
If there are two or more keypads fitted to the system, all
keypads except the one in use will display SYSTEM INHIB-
ITED during engineering.
The telephone line has become disconnected or faulty. If
possible check the connection to the panel. If the message
persists, contact the installing company.
The circuit connected to the unit tamper terminals has become
open circuit. Check the external sounder wiring. If an SAB is
not fitted check that TR and 0V are linked.
A mains transient or severe electrostatic discharge has upset
the system software. The system has restarted itself and
should be functioning normally. If the system is appearing
to malfunction or this message frequently appears in the log,
contact your installing company.
One or more zones are on 14 day test (soak test). Some of these
zones have been violated during the set period and would have
caused and alarm. Contact your installing company. The panel
will continue to operate correctly.