OUTPUT 2: Cellular Module or Network Trouble - Output is normally high and switches to ground when
the 3G4010/LE4010 cannot communicate with the network.
OUTPUT 3: Power Supply or Battery Trouble - Output is normally high and switches to ground when a
problem with the power source is detected.
OUTPUT 4: General Module Trouble - Output is normally low and switches to high when a Cellular Net-
work Trouble, Power Supply/Battery Trouble, and/or a Failure to Communicate (FTC) trouble is detected.
Note: PGM4 must be connected to the control panel as shown in Figure 4 (Residential applications) or Figures
8-9 (Commercial applications). Program the control panel input Zone/Point as 24hr 'Supervisory' with keypad-
only notification when activated. Output 4 on the 3G4010/LE4010 must be set as 'Active High'.
Note: Once an output has been activated automatically, it will not restore until all the causes of activation are
cleared.

5.6 Reporting Codes

3G4010/LE4010 Reporting Codes CID
Zone 1 Activation
Zone 1 Restoral
Zone 2 Activation
Zone 2 Restoral
Zone 3 Activation
Zone 3 Restoral
Zone 4 Activation
Zone 4 Restoral
PSTN Line Down
PSTN Line Restoral
Input Loss
Input Restoral
Low Battery Alert
Low Battery Restoral
Periodic Test
Periodic Test with Trouble
Radio Activation
Internal Buffer Full
FTC Restoral
Firmware Update Successful
Firmware Update Fail
Firmware Update Begin
System Tamper
System Tamper Restore
* C24 Communications default value
SIA
Programmable Comments
E11A 991
FA 991
YES
R11A 991
FH 991
YES
E12A 992
PA 992
YES
R12A 992
PH 992
YES
E13A 993
BA 993
YES
R13A 993
BH 993
YES
E3AA 994
YX 994
YES
R3AA 994
YZ 994
YES
E351 000
LT 000
FIXED
R351 000
LR 000
FIXED
E337 000
YP 000
FIXED
R337 000
YQ 000
FIXED
E338 000
YT 000
FIXED
R338 000
YR 000
FIXED
E603 XXX RP XXX
FIXED
E608 XXX RY XXX FIXED
R552 000
RS 000
FIXED
E624 000
JL 000
FIXED
R354 000
YK 000
FIXED
R901 000
LS 000
FIXED
E902 000
LU 000
FIXED
E901 000
LB 000
FIXED
E145 000
ES 000
FIXED
R145 000
EJ 000
FIXED
18
5.6 Reporting Codes
Delayed 24 Hour Fire *
Delayed 24 Hour Fire Restore *
Panic Alarm *
Panic Alarm Restore*
Burglary *
Burglary Restore *
System Trouble *
System Trouble Restore *
Telco 1 Fault
Telco 1 Fault Restore
Power Supply Trouble
Power Supply Trouble Restore
Transmitter Battery Trouble
Transmitter Battery Restore
Test Transmission <Receiver Path>
Test Transmission <Receiver Path>
Remote Programming Successful
Communications Restored
Expansion Module Tamper
Expansion Module Tamper Restore