CAUTION - Never use:
Bleach, chlorine products and other corrosive
chemicals
Liquids containing solvents (i.e., paint thinner,
gasoline, oils)
Tri-sodium phosphate products
Ammonia products
Acid-based products
These chemicals will harm the machine and will
damage the surface being cleaned.
Shutting Down & Clean-Up
STEP 1: Remove detergent suction
tube from container and insert into
one (1) gallon of fresh water. Pull
trigger on spray gun and siphon
water for one minute.
STEP 4: Squeeze trigger on spray
gun to relieve remaining pressure.
STEP 2: Turn burner switch off and
continue spraying, allowing the
water to cool to below 100°F.
STEP 5: Remove water supply
hose.
Landa PDHW Series Operator's Manual 8.919-980.0 - B

Rinsing

It will take a few seconds for the detergent to clear.
Apply safety latch to spray gun. Remove black soap
nozzle from the quick coupler. Select and install the
desired high pressure nozzle.
NOTE: You can also stop detergent from flowing by
simply removing detergent siphon tube from bottle.
Burner
Switch
Operations
Engine
Key Switch
STEP 3: Turn engine key switch off
and turn off water.