Step 3
BO12
1 Positioning
The height from the bottom of post to the bottom of rear roof channel is 8'-8 1/2" (265,4
cm) minimum to 9' (274,3 cm) maximum. For unit installed over a door, in order to maintain door clearance,
the minimum height above door is 6" (15,2 cm). If distance is less than 8'-8 1/2" (265,4 cm), bottom of posts
will have to be trimmed (with hacksaw) in order to obtain 2 1/2" (6,4 cm) slope. If this is necessary, drill two
new holes in post and re-attach anchor. For installation where a door is not involved, do not block windows
with rear roof channels. Once dimensions are established, level rear roof channels and mark structure.
Level
9665
2 Channel Weather Stripping
end, on the outside of rear roof channel. Making sure weather stripping is ush with top ange of rear roof
channel, continue to stick weather stripping to rear roof channels. Peel paper backing.
Parts Needed For
Mounting Rear Roof
Channel to Structure
6" (15,2 cm) Min.
9734
Concrete
Attach weather stripping 1/2x 1 1/2 (13 mm x 3,8 cm) to one
1/2x1 1/2 (13 mm x 3,8 cm)
Weather Seal
9665
8'-8 1/2" (265,4 cm) Min.
9' (274,3 cm) Max.
Rear Roof Channel Assembly
12
Rear Roof Channel Assembly (one)
66627 Weather Seal
1/2x 1 1/2 (13 mm x 3,8 cm) (one)
Post
END VIEW