KSB Filtra N Installation And Operating Manual
KSB Filtra N Installation And Operating Manual

KSB Filtra N Installation And Operating Manual

Recirculation pump for swimming pool filter systems
Hide thumbs Also See for Filtra N:

Advertisement

Quick Links

Recirculation Pump for Swimming Pool
Filter Systems
Filtra N
Installation/Operating
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Filtra N and is the answer not in the manual?

Questions and answers

Summary of Contents for KSB Filtra N

  • Page 1 Recirculation Pump for Swimming Pool Filter Systems Filtra N Installation/Operating Manual...
  • Page 2 Legal information/Copyright Installation/Operating Manual Filtra N Original operating manual KSB Aktiengesellschaft All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without KSB's express written consent.
  • Page 3: Table Of Contents

    Checks to be carried out prior to installation ..........15 Installing the pump set .................. 16 Connecting the piping ...................16 Connection to power supply ................17 Priming and venting the pump ..............18 Checking the direction of rotation ..............18 Commissioning/Start-up/Shutdown ...........19 Filtra N 3 of 34...
  • Page 4 Spare parts stock ..................... 26 Drainage/disposal ................... 26 Trouble-shooting ................27 Related Documents ................2 8 Exploded view and list of components ............28 Wiring diagram ....................29 EC Declaration of Conformity ............30 Certificate of Decontamination ............31 Index ....................32 4 of 34 Filtra N...
  • Page 5: Glossary

    Hydraulic system The part of the pump in which the kinetic energy is converted into pressure energy Noise characteristics The noise emission to be expected, indicated as sound pressure level LpA in dB(A) Filtra N 5 of 34...
  • Page 6: General

    In the event of damage, immediately contact your nearest KSB service centre to maintain the right to claim under warranty. Noise characteristics(⇨ Section 4.6 Page 14) 1.2 Symbols...
  • Page 7: Safety

    ▪ Only use the pump to handle the fluids described in the data sheet or product literature of the pump model. ▪ Never operate the pump without the fluid handled. ▪ Observe the minimum flow rates indicated in the data sheet or product literature (to prevent overheating, bearing damage, etc). Filtra N 7 of 34...
  • Page 8: Personnel Qualification And Training

    2.7 Safety information for the operator/user ▪ Fit contact guards supplied by the operator for hot, cold or moving parts, and check that the guards function properly. ▪ Do not remove any contact guards during operation. 8 of 34 Filtra N...
  • Page 9: Safety Information For Maintenance, Inspection And Installation Work

    Never operate the pump (set) outside the limits stated in the data sheet and in this manual. The warranty relating to the operating reliability and safety of the supplied pump (set) is only valid if the equipment is used in accordance with its intended use.(⇨ Section 2.3 Page 7) Filtra N 9 of 34...
  • Page 10: Transport/Temporary Storage/Disposal

    On transfer of goods, check each packaging unit for damage. In the event of in-transit damage, assess the exact damage, document it and notify KSB or the supplying dealer (as applicable) and the insurer about the damage in writing immediately.
  • Page 11: Disposal

    Collect greases and other lubricants during dismantling. Separate and sort the pump materials, e.g. by: - Metals - Plastics - Electronic waste - Greases and other lubricants Dispose of materials in accordance with local regulations or in another controlled manner. Filtra N 11 of 34...
  • Page 12: Description Of The Pump (Set)

    ▪ With integrated filter basket for recirculation and pre-filtering Pump for handling clear, chlorinated or treated water as well as seawater and brackish water. 4.2 Designation Example: Filtra N 6 E Table 3: Key to the designation Code Description Filtra N Type series Size;...
  • Page 13: Configuration And Function

    The shaft passage through the cover is sealed towards the atmosphere with a shaft seal (4). The shaft runs in a rolling element bearing. Sealing The pump is sealed by a mechanical seal with rotating torque-transmitting elements. Filtra N 13 of 34...
  • Page 14: Noise Characteristics

    22 D 24 D 30 D 4.7 Scope of supply Depending on the model, the following items are included in the scope of supply: ▪ Pump set Accessories Required accessories can be purchased from our distributors. 14 of 34 Filtra N...
  • Page 15: Installation At Site

    ▪ Check the data on the name plate of the pump to make sure it can be operated on the available mains. ▪ The fluid to be handled matches the description of suitable fluids. ▪ The above safety instructions have been complied with. Filtra N 15 of 34...
  • Page 16: Installing The Pump Set

    5 Installation at Site 5.3 Installing the pump set Fig. 3: Filtra N installation Suction lift operation Suction head operation Suction lift NOTE For operating the pump set in suction lift operation, make sure the suction lift does not exceed 3 metres.
  • Page 17: Connection To Power Supply

    Select an appropriate start-up method. Connect the pump set in accordance with the wiring diagram.(⇨ Section 9.2 Page 29) NOTE We recommend to fit a thermal motor protection switch if pumps with three-phase motors are used. Filtra N 17 of 34...
  • Page 18: Priming And Venting The Pump

    The motor's direction of rotation must match the arrow indicating the direction of rotation on the pump. If the motor runs in the wrong direction of rotation, check the electrical connection of the motor and the control system, if applicable. 18 of 34 Filtra N...
  • Page 19: Commissioning/Start-Up/Shutdown

    0 to +35 ℃ Fluid temperature 0 to +60 ℃ Ambient temperature Voltage/frequency, alternating current 230 V / 50 Hz Voltage/frequency, three-phase current 230 V / 400 V / 50 Hz Max. suction lift Enclosure IP 44 Filtra N 19 of 34...
  • Page 20: Shutdown/Storage/Preservation

    Risk of personal injury from moving parts or escaping fluid! ▷ As soon as the work is complete, re-install and/or re-activate any safety-relevant and protective devices. NOTE If the pump has been out of service for more than one year, replace all elastomer seals. 20 of 34 Filtra N...
  • Page 21: Servicing/Maintenance

    Hot surface Risk of injury! ▷ Allow the pump set to cool down to ambient temperature. 7.2.1 Inspection work 7.2.1.1 Cleaning the filter basket Fig. 5: Filter basket Make sure the filter basket is cleaned regularly. Filtra N 21 of 34...
  • Page 22 For dismantling and reassembly observe the exploded views and the general assembly drawing.(⇨ Section 9.1 Page 28) NOTE All maintenance, service and installation work can be carried out by KSB Service or authorised workshops. Find your contact in the attached "Addresses" booklet or on the Internet at "www.ksb.com/contact".
  • Page 23 Lift off the motor together with the pump's hydraulic system. 7.2.2.3 Dismantling the impeller Fig. 7: Dismantling the impeller ✓ The motor has been removed.(⇨ Section 7.2.2.2 Page 23) Remove diffuser 171. Remove impeller 230. Filtra N 23 of 34...
  • Page 24 ✓ Any damaged or worn parts have been replaced by original spare parts. ✓ The sealing surfaces have been cleaned. Wet the rubber surfaces of mechanical seal 433 with soapy water to facilitate the assembly. 24 of 34 Filtra N...
  • Page 25 Fig. 11: Mounting the motor ✓ The impeller has been fitted as described.(⇨ Section 7.2.3.2 Page 25) Position the motor together with the pump's hydraulic system. Fit pins 563. Connect the motor to the power supply. Filtra N 25 of 34...
  • Page 26: Spare Parts Stock

    Table 6: Quantity of spare parts for recommended spare parts stock Part No. Description Number of pumps (including stand-by pumps) 10 and more Rolling element bearing 20 % Mechanical seal 20 % 7.4 Drainage/disposal Undo screws 912 to drain the pump.(⇨ Section 9.1 Page 28) 26 of 34 Filtra N...
  • Page 27: Trouble-Shooting

    Increase the voltage or increase the core cross-sections. Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure. Disconnect the pump from the power supply and allow it to cool down. Filtra N 27 of 34...
  • Page 28: Related Documents

    4x(900.02) (833) 1x(412.04) F iltra N 22; 24; 30 (160) 1x(412.01) 1x412.01 (832) (230) (831) (745) 4x(900.02) (745.01) 1x(412.03) Filtra N 6; 8; 12; 14; 18 (331) (81.59) (420) (81.93) 81-59 (837) 4x(900) (331) 4X(563) (818) (89-12) (932) (101) (81-23)
  • Page 29: Wiring Diagram

    9 Related Documents 9.2 Wiring diagram 230 V 400 V 230 V Fig. 13: Wiring diagram Filtra N 29 of 34...
  • Page 30: Ec Declaration Of Conformity

    128, rue Carnot, 59320 Sequedin/Lille (France) The manufacturer herewith declares that the product: Filtra N Series code: S 1001 - S 1452 ▪ is in conformity with the provisions of the following Directives as amended from time to time: – Pump (set): Machinery Directive 2006/42/EC The manufacturer also declares that ▪...
  • Page 31: Certificate Of Decontamination

    We confirm that the above data and information are correct and complete and that dispatch is effected in accordance with the relevant legal provisions....................................Place, date and signature Address Company stamp Required fields Filtra N 31 of 34...
  • Page 32: Index

    Safety 7 Disposal 11 Safety awareness 8 Scope of supply 14 Shaft seal 13 Shutdown 20 Spare parts stock 26 Intended use 7 Storage 20 Misuse 8 Trouble-shooting 27 Noise characteristics 14 Operating limits 7 32 of 34 Filtra N...
  • Page 34 KSB S.A.S. 128, rue Carnot • 59320 Sequedin/Lille (France) B.P. 60095 • 59482 Haubourdin Cedex (France) Tel. +33 3 2022-7000 • Fax +33 3 2022-7099 www.ksb.com...

Table of Contents