Message Configuration

Parameter
Function
MSG1EN
Whether this message is enabled.
0 - Disabled
1 – Enabled
MSG1IDL
The low word value of the message identifier. This will contain the
decimal value of the lower word (2 bytes) of the ID.
MSG1IDH
The high word value of the message identifier. This will contain the
decimal value of the higher word (2 bytes) of the ID. Not necessary if the
DSC is set for 11 bit identifiers (CAN 2.0a)
MSG1PL
Message packet length. This value sets the number of data bytes contained
in the message.
0 to 8
MSG1B1
Set the byte value of byte 1 in the message.
0 to 255
MSG1B2
Set the byte value of byte 2 in the message.
0 to 255
MSG1B3
Set the byte value of byte 3 in the message.
0 to 255
MSG1B4
Set the byte value of byte 4 in the message.
0 to 255
MSG1B5
Set the byte value of byte 5 in the message.
0 to 255
MSG1B6
Set the byte value of byte 6 in the message.
0 to 255
MSG1B7
Set the byte value of byte 7 in the message.
0 to 255
MSG1B8
Set the byte value of byte 8 in the message.
0 to 255
MSG1SRC
Set the index of the parameter whose data is to be inserted into the
outgoing packet. This data will be formatted and placed at the specified
position in the message.
23