QUICK OVERVIEW TEST MODE — See page 4 to access Quick Overview Test Mode.
Press the START button to begin the Quick Overview Test. IMPORTANT: Lid must be closed and locked to perform
Quick Overview Test.
FUNCTION
Recommended Procedure
(Status LED names may vary between makes and models)
LID WILL LOCK
Motor must be at "0" RPM. If lid does not lock, go to Manual Overview Test: Lid Lock, page 9.
COLD VALVE WILL ACTUATE
If water is not present, or temperature is wrong, go to Manual Overview Test: Cold Valve, page 9.
HOT VALVE WILL ACTUATE
If water is not present, or temperature is wrong, go to Manual Overview Test: Hot Valve, page 9.
SHIFTER MOVES TO AGITATION POSITION
MOTOR AGITATES
If motor does not agitate, go to Manual Overview Test: Gentle or Heavy Agitation, page 9.
DRAIN PUMP WILL ACTUATE
If water is not draining, go to Manual Overview Test: Drain, page 9.
SHIFTER MOVES TO SPIN POSITION
MOTOR SPINS
If basket is not turning, go to Manual Overview Test: Low or High Spin, page 9.
LID REMAINS LOCKED UNTIL WASHER SENSES A STOPPED
BASKET
Basket must stop spinning (0 RPM) before test continues to next phase. Time for basket to stop spinning may vary
from 30 seconds up to 2 minutes.
LID WILL UNLOCK AND CYCLE COMPLETES
If lid does not unlock, go to Manual Overview Test: Lid Lock, page 9.
PAGE 8
FOR SERVICE TECHNICIAN'S USE ONLY
STATUS LEDs
1
On
2
On
2
1
On
4
On
4
1
On
4
2
On
4
2
1
On
8
On
8
1
On
8
2
DO NOT REMOVE OR DESTROY
= ON
Est. TIME
In Seconds
1
60
10
~5-15
10
Till Empty
~5-15
10
~30-45
1
~3 min

Hide quick links: